5
Adjustment > Adjustment at Time of Parts Replacement
5. Open the inserter, and then loosen the two hinge fixing screw (M4) [1].
6. Loosen the two screws securing the hinge.
7. Remove the nut cap, loosen the hexagon nut, and turn the adjusting screw [3] using an Allen
wrench. Make adjustment with reference to the marks [4] on the front plate. Turning the adjusting
screw by one scale mark (1 mm) moves the front of the inserter 4.6 mm to the left/right.
- Turning the adjusting screw clockwise moves the plate forward and moves the inserter to
leftward.
- Turning the adjusting screw counterclockwise moves the plate backward and moves the inserter
to rightward.
5
Adjustment > Adjustment at Time of Parts Replacement
[1]
F-5-6
F-5-6
[1]
F-5-7
F-5-7
8. Tighten the two hinge fixing screws [1].
9. Repeat step 7 until the positioning pin enters the frame hole completely.
x1
[1]
F-5-8
F-5-8
F-5-9
F-5-9
F-5-10
F-5-10
5-3