Dynabrade Electric Dynafile II 40501 Safety, Operation And Maintenance Manual

Dynabrade Electric Dynafile II 40501 Safety, Operation And Maintenance Manual

Advertisement

Electric Dynafile
Models:
40500 – 120 V / 60 Hz
40501 – Versatility Kit
Read and understand this tool manual before operating your tool. Follow all safety rules for the protection of operating personnel
as well as adjacent areas. For safety information, refer to Safety Requirements for the Use, Care and Protection of Abrasive Wheels
– ANSI B7.1, Code of Federal Regulation – CFR 29 Part 1910, European Committee for Standards (EN) Hand Held Electric Motor
Operated Tools – Safety Requirements and applicable State and Local Regulations.
Read and understand tool manual before
work starts to reduce risk of injury to
operator, visitors, and tool.
Eye protection must be worn at all times,
eye protection to conform to ANSI Z87.1.
Respiratory protection to be used when exposed to
contaminants that exceed the applicable threshold
limit values required by law.
WARNING! Read and understand all instructions. Failure to follow all instructions listed below, may result in electric shock, fire and/or serious personal injury.
Work Area
1. Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents.
2. Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. Power tools create sparks which ignite
the dust or fumes.
3. Keep bystanders, children, and visitors away while operating a power tool. Distractions can cause you to lose control.
Electrical Safety
1. Double Insulated tools are equipped with a polarized plug (one blade is wider than the other). This plug will fit in polarized outlet only one way. If the plug
does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install a polarized outlet. Do not change the plug in
any way. Double Insulation
2. Avoid body contact with grounded surfaces such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric shock if your body is grounded.
3. Don't expose power tools to rain or wet conditions. Water entering a power tool will increase the risk of electric shock.
4. Do not abuse the cord. Never use the cord to carry the tools or pull the plug from an outlet. Keep cord away from heat, oil, sharp edges or moving parts.
Replace damaged cords immediately. Damaged cords increase the risk of electric shock.
Tool Manual – Safety, Operation and Maintenance
SAVE THIS DOCUMENT, EDUCATE ALL PERSONNEL
SAFETY LEGEND
WARNING
WARNING
WARNING
GENERAL SAFETY RULES
SAVE THESE INSTRUCTIONS
eliminates the need for the three wire grounded power cord and grounded power supply system.
®
II
WARNING
Practice safety requirements. Work alert,
have proper attire, and do not operate tools under
the influence of alcohol or drugs.
Ear protection to be worn when exposure to sound,
exceeds the limits of applicable Federal, State or
local statues, ordinances and/or regulations.
Electric shock hazard. Avoid bodily contact with
grounded objects, bodies of water.
Do not damage cord set.
(continued on next page)
Parts Page Reorder No. PD04•17
Effective March, 2004
Supersedes PD02•42
WARNING
WARNING
WARNING

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Electric Dynafile II 40501 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dynabrade Electric Dynafile II 40501

  • Page 1 Parts Page Reorder No. PD04•17 Effective March, 2004 Supersedes PD02•42 Electric Dynafile ® Tool Manual – Safety, Operation and Maintenance SAVE THIS DOCUMENT, EDUCATE ALL PERSONNEL Models: 40500 – 120 V / 60 Hz 40501 – Versatility Kit WARNING Read and understand this tool manual before operating your tool. Follow all safety rules for the protection of operating personnel as well as adjacent areas.
  • Page 2 Important: A preventative maintenance program is recommended whenever portable power tools are used. • Use only genuine Dynabrade replacement parts to insure quality. To order replacement parts, specify Model #, Serial # and SFPM of your tool. Routine Preventative Maintenance: •...
  • Page 3: Important Operating And Safety Instructions

    Our obligation is contingent upon proper use of Dynabrade tools in accordance with factory recommendations, instructions and safety practices. It shall not apply to equipment which has been subject to misuse, negligence, accident or tampering in any way so as to affect its normal performance.
  • Page 4: Housing Assembly

    Housing Assembly Index Key No. Part # Description 1 Contact Arm Assembly (See Chart on pg.6) 2 96334 Plug 3 15308 Guide Post 4 11040 Spring 5 15306 Tension Arm 6 95426 Spring 7 95218 Knob Assembly 8 15309 Dust Cover 9 15307 Tension Shaft 10 15329 Screw 11 15312 Belt Guard...
  • Page 5 Angle-Head Assembly and Assemblies Brush Set Assembly Index Key No. Part # Description 1 42710 Screw (4) 10 42719 Retaining Ring 18 42729 Switch 2 42711 Gear Case Cover 11 42720 Upper Spindle Bearing 19 42730 Cord Protector 3 42712 Spindle 3/8"-24 12 42721 Lock Pin 20 42731 Cord Set To order replacement parts,...
  • Page 6 ® Electric Dynafile II Contact Arms Optional 40078 Adapter allows use of 24" long belts; extends reach to Arms for 4" to 17" workable reach. 7" when used with contact arm. Note: For belt widths greater than 1/2" use drive wheel 15336 to eliminate slippage. 11286 11024 steel platen available.
  • Page 7 Electric Dynafile ® II Contact Arm Assembly Parts List Contact Wheel Assembly – Includes wheel, bearings and shaft. Bearing Contact Wheel Contact Arm Bearing Shaft ® Electric Dynafile II Standard Contact Arms Part Abrasive Contact Wheel Contact Wheel Contact Wheel Bearing Number Belt Size...
  • Page 8: Optional Accessories

    Visit Our Web Site: www.dynabrade.com Email: Customer.Service@Dynabrade.com DYNABRADE, INC., 8989 Sheridan Drive • Clarence, NY 14031-1490 • Phone: (716) 631-0100 • Fax: 716-631-2073 • International Fax: 716-631-2524 DYNABRADE EUROPE S.àr.l., Zone Artisanale • L-5485 Wormeldange—Haut, Luxembourg • Telephone: 352 76 84 94 1 • Fax: 352 76 84 95 1 ©...