Download  Print this page

Replacing The Current Transformer; Image - Siemens SINAMICS SM120 Operating Instructions & Installation Instructions

Motor module.
Hide thumbs

Advertisement

9.7.5

Replacing the current transformer

Removing the current transformer
To remove the current transformer, proceed as follows:
1. Remove the power cables which are screwed to the busbar.
2. Loosen the screw
3. Loosen and remove the screw
4. Remove the connecting cable between the current transformer and the AVT combination
5. Loosen the four screws
SINAMICS SM120 6SL38855?B
Operating Instructions 12/2015
at the busbar and remove the measuring resistor.
Ensure that the cable of the measuring resistor is not damaged.

Image 9-5

Replacing the current transformer
module. To do this, loosen the nuts on the side of the current transformer and remove the
cables
.
at the busbar.
that fix the current transformer to the busbar.
Maintenance
9.7 Repair
107