EN 24
5.
LC7.1A LA
Table 5-4 Error code overview
Error
1)
code
Description
0
No error.
1
DC Protection of
speakers.
2
+12V protection error.
3
Reserved.
4
General I2C error.
5
Trident Video
Processor
communication error.
6
I2C error while
communicating with
the NVM.
7
I2C error while
communicating with
the Tuner.
8
I2C error while
communicating with
the IF Demodulator.
9
I2C error
communicating with
the Sound Processor.
10
SDRAM defective.
11
I2C error while
communicating with
the HDMI IC.
12
I2C error while
communicating with
the MOJO PNX8314.
13
DVB HW
communication error.
14
SDRAM defective.
15
Reserved.
16
Reserved.
17
I2C error while
communicating with
the FPGA AmbiLight
bolt-on module.
18
I2C error while
communicating with
the iBoard processor.
19
I2C error while
communication with
1080p bolt-on module.
Notes
1. Some of the error codes reported are depending on the
option code configurations.
2. This error means: no I2C device is responding to the
particular I2C bus. Possible causes: SCL/SDA shorted to
GND, SCL shorted to SDA, or SCL/SDA open (at uP pin).
The internal bus of the Trident platform should not cause
the entire system to halt as such an error can be reported.
Service Modes, Error Codes, and Fault Finding
Item
nr.
Remarks
12V missing or "low".
note 2
7202 When Trident IC is
defective, error 10
and 14 might also be
reported. Trident
communicates via
parallel bus, not via
the I2C bus. The I2C
bus of Trident is only
used in ComPair
mode.
7315 The TV will not start-
up due to critical data
not available from the
NVM, but the LED
will blink the error
code.
1101
7113
7411
7204
7817
7G00 if applicable
7F01,
if applicable
7K00,
7G00
7205
if applicable
if applicable
if applicable
5.4.4
How to Clear the Error Buffer
The error code buffer is cleared in the following cases:
By using the CLEAR command in the SAM menu:
To enter SAM, press the following key sequence on the
remote control transmitter: "062596" directly followed
by the OSD/i+ button (do not allow the display to time
out between entries while keying the sequence).
Make sure the menu item CLEAR is selected. Use the
MENU UP/DOWN buttons, if necessary.
Press the MENU RIGHT button to clear the error
buffer. The text on the right side of the "CLEAR" line will
change from "CLEAR?" to "CLEARED"
If the contents of the error buffer have not changed for 50
hours, the error buffer resets automatically.
Note: If you exit SAM by disconnecting the mains from the
television set, the error buffer is not reset.