Airbridge BTS3606E&3606AE
System Commissioning Guide
Step 1 Enter the following command:
CHK CBTSSWVER
Step 2 Click
Step 3 Specify the values of the parameters.
For example: CHK CBTSSWVER: BTSID=1;
For the detailed explanation of the parameters, see the online help.
Step 4 Click
----End
3.4.4 Querying Availability of BTS Cells
To query the availability of BTS cells, do as follows:
Step 1 Enter the command DSP RES.
Step 2 Click
Step 3 Specify the values of the parameters. For detailed explanation of the parameters, see the
online help.
For example: DSP RES:;
Step 4 Click
----End
3.4.5 Querying Active Alarms of the BTS
To query the active alarms of the BTS, do as follows:
Step 1 Enter the command LST ALMFE.
Step 2 Click
Step 3 Specify the values of the parameters.
For detailed explanation of the parameters, see the online help.
For example: LST ALMFE: CNT=20; (CNT is the returned record number.)
Step 4 Click
----End
3.4.6 Querying the Configuration Data of the BTS
To query the configuration data of the BTS, do as follows:
Step 1 Execute the command DSP CBTSCFG to query the configuration data of the BTS.
Step 2 Click
Issue 02 (2006-10-10)
or press Enter.
or press F9 to execute the command.
or press Enter.
or press F9 to execute the command.
or press Enter.
or press F9 to execute the command.
or press Enter.
Huawei Technologies Proprietary
3 Commissioning Process
3-19
Need help?
Do you have a question about the Airbridge BTS3606E and is the answer not in the manual?
Questions and answers