Download Print this page

Specifications; Ordering Information - Honeywell VR8204 Series Manual

Intermittent pilot dual automatic valve combination gas controls
Hide thumbs

Advertisement

VR8204; VR4204
SPECIFICATIONS • ORDERING INFORMATION
IMPORTANT: The specifications given in this publica-
tion do not include normal manufacturing toler-
ances. Therefore, this unit may not exactly match the
listed specifications. Also this product is tested and
calibrated under closely controlled conditions, and
some minor differences in performance can be ex-
pected if those conditions are changed.
®
TRADELINE
MODELS
TRADELINE controls are selected and packaged to
provide ease of stocking, ease of handling and maximum
replacement value. TRADELINE model specifications are
the same as those of standard models except as noted
below.
TRADELINE MODEL AVAILABLE: VR8204A Dual
Automatic Combination Gas Control for Intermittent
Pilot Systems. Models for natural or LP gas.
Opening
Model No.
Charac-
Suffix Letter
teristic
Standard
VR8204A,M
VR4204M
VR8204C,P
Step-
VR4204P
opening
VR8204H,K
Slow-
VR4204H
opening
a
Step pressure is not adjustable.
When purchasing replacement and modernization products from your TRADELINE
sheets for complete ordering number, or specify:
1. Order number, TRADELINE, if desired.
2. Natural or LP gas.
3. Step pressure on VR4204C,P and VR8204C,P.
4. Accessories, if desired.
5. Order separately: pilot burner, igniter-sensor, transformer, limit controller, and thermostat or controller as required.
If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:
1. Your local Honeywell Home and Building Control Sales Office (check white pages of your phone directory).
2. Home and Building Control Division Customer Satisfaction
Honeywell Inc., 1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386 (612) 951-1000
In Canada—Honeywell Limited/Honeywell Limitee, 740 Ellesmere Road, Scarborough, Ontario M1P 2V9. International Sales
and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan,
Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
68-0047—2
TABLE 1—MODEL SPECIFICATIONS.
Standard Factory
Regulator Settings
Type
of Gas
in. wc
Natural
3.5
LP
10.0
Natural
Step—0.7, 0.9,
Step—0.17 0.22,
1.2 or 1.7,
a
as ordered
Full Rate—3.5
Full Rate—0.9
LP
Step—1.4, 2.5,
Step—0.35, 0.62,
4.0 or 5.5,
a
as ordered
Full Rate—10
Full Rate—2.5
Natural
3.5
LP
10.0
ADDITIONAL FEATURES:
• 3/8 in. bushing.
• 3/4 in. straight flange assembly (with O-ring and
screws).
• Tool for flange hex screws.
• Pilot compression fitting.
STANDARD MODELS
MODELS: VR8204 and VR4204 Dual Automatic Valve
Combination Gas Controls for use in Intermittent Pilot
Systems. VR8204 for use with S8600, S8610 and S8620
Modules. VR4204 for use with 120 Vac modules. See
Table 1 for model specifications.
SUPPLY VOLTAGE:
VR4204: 120 Vac, 60 Hz.
VR8204: 24 Vac, 60 Hz.
(50/60 Hz models available on request.)
Optional Factory
Regulator Settings
kPa
in. wc
0.9
3 to 5
2.5
8 to 12
Step—0.7,
0.30 or 0.48
0 9, 1.2 or
a
a
as ordered
1 7 as ordered
Full Rate—3 to 5
Step—1.4, 2.5,
0.99 or 1.37
4.0 or 5.5,
a
a
as ordered
as ordered
Full Rate—
8 to 12
0.9
3 to 5
2.5
8 to 12

Ordering Information

®
wholesaler or your distributor, refer to the price
2

Specifications

Range of Field
Adjustment
kPa
in. wc
0.7 to 1.2
3 to 5
2 to 3
8 to 12
Step—0.17 0.22,
Step—
0.30 or 0.48,
none;
a
Full
as ordered
Rate—
Full Rate—
3-5
0.7 to 1.2
Step—0.35, 0.62,
Step—
0.99 or 1.37,
none;
a
Full
as ordered
Rate—
Full Rate—2 to 3
8-12
0.7 to 1.2
3 to 5
2 to 3
8 to 12
kPa
0.7 to 1.2
2 to 3
Step—
none;
Full
Rate—
0.7 to 1.2
Step—
none;
Full
Rate—
2 to 3
0.7 to 1 2
2 to 3

Hide quick links: