INSUFFICIENT FLOW
A. Ensure the service shut-off valve is fully open (provided by installer).
B. Ensure water supply is within the normal operating range of 40-60 psi.
1. If pressure is too low, fl ow can be drastically reduced.
2. If pressure is too high, the strainer and/or valve may have been damaged.
3. The unit is rated for a maximum range of 30-105 psi.
C. Inspect the unit's valve for damage, and replace if necessary.
D. Inspect the inline strainer for damage and/or clogging, and clean or replace as necessary.
E. Check all fi ttings and tubing for damage and leaks. Replace components as necessary.
UNIT HAS PROBLEMS DRAINING
A. Remove any debris from the drain.
B. Remove any debris from the PVC pipe and fi ttings.
C. Check and clear the waste trap (provided by installer).