8
Press the M(+)/m(–) buttons to select
(PHASE)
and press the OK button.
The PHASE menu appears on the screen.
9
Press the M(+)/m(–) buttons until the horizontal
stripes are at a minimum.
Adjust so that the horizontal stripes are at a minimum.
,
10
Click [END] on the screen to turn off the test pattern.
To reset the automatic picture quality adjustment
Select SCREEN RESET and activate it using the RESET menu. For more
information on using the RESET menu, see “Resetting the adjustments
(RESET)” on page 16.
Note
When using digital RGB signals, you do not need to set the PHASE or
PITCH.
Adjusting the picture position
GB
(H CENTER/V CENTER) (Analog
RGB signal only)
If the picture is not in the center of the screen, adjust the picture’s
centering as follows.
These settings may have to be repeated if you change the input
signal after reconnecting your computer.
1
Start the Utility Disk and display the test pattern.
Repeat steps 2 and 3 of “Eliminating flicker or blurring
(PHASE/PITCH) (Analog RGB signal only).”
2
Press the MENU button.
The main menu appears on the screen.
3
Press the M(+)/m(–) buttons to select
(H
CENTER) or
(V CENTER) and press the OK
button.
The H CENTER or V CENTER menu appears on the screen.
4
Move the picture up, down, left, or right until the
frame at the perimeter of the test pattern
disappears.
Press the M(+)/m(–) buttons to adjust the picture’s
centering using the H CENTER menu for horizontal
adjustment, or the V CENTER menu for vertical
adjustment.
5
Click [END] on the screen to turn off the test pattern.
Note
When using digital RGB signals, you do not need to set the H CENTER
or V CENTER.
Page 13