DRAINING THE FUEL TANK
Drain and clean the fuel tank each year, or before storing the generator for longer than two months.
To drain the fuel tank and carburetor:
1. Using a Phillips-head screwdriver (not included), remove the
service panel on the opposite side of the recoil starter by un-
screwing the top two screws (Fig. 23 - 1).
2. Locate the carburetor and the transparent drain tube that
extends down through the base plate of the generator (Fig. 31).
3. Prepare an approved gasoline-storage container and direct
the end of the transparent tube into the container.
4. Remove the fuel cap. Turn the 3-in-1 dial switch to the "RUN"
position (Fig. 32). This will open up the fuel valve.
5. Open up the carburetor drain screw (Fig. 31) with a flat-head
screwdriver (not included). Fuel will start draining from the car-
buretor and fuel tank through the drain tube.
NOTE: The draining process may take a few hours, depending
on the amount of fuel in your gas tank.
6. Once fuel is completely drained from the tube, reinstall the
fuel cap and turn the 3-in-1 switch to "OFF" position. Tighten
the drain screw with the screwdriver and reinstall the service
panel.
7. Start and run the generator until the fuel runs out.
8. Store the emptied gasoline in a suitable place. DO NOT store
flammable materials near the gasoline.
CAUTION:
Store the emptied gasoline in a suitable place. Never store fuel for more than 2 months.
30
MAINTENANCE
Drain Tube
Carburetor
Drain Screw
Fig. 31
Fig. 32