Honeywell EK280 Operating Instructions Manual page 92

Volume conversion device
Hide thumbs Also See for EK280:
Table of Contents

Advertisement

92
Message
z Warning
Vm warning
Update error
Softw. error
Sett. error
I2 Warn.sig.
I3 Warn.sig.
I4 Warn.sig.
I5 Warn.sig.
I6 Warn.sig.
T2 Warn Lim.
p2 Warn Lim.
Batt. low
c) Signals:
TA Warn Lim.
Repair mode
Clock n. set
Meaning, action
The sum of gas analysis values for AGA-8 DC92 is
more or less than 100%. An accurate calculation of the
real gas factor and the compressibility ratio factor can
therefore not be carried out.
If a HF-NF switch is configured, then this message is
enabled in the event of a fault at the HF input, e.g. loss
of external power supply.
Before the software update, an error was detected in
the cached software image.
This message is used for factory diagnosis.
Please contact the Elster support (see chapter 1.3
"Customer service").
The programming of the device has generated an unusable
combination of settings.
Please contact the Elster support (see chapter 1.3 "Customer
service").
If an input has been configured as a warning input, this
message will be displayed if an active signal appears at
the corresponding terminal (e.g. terminal DE2).
The input configuration can be adjusted using the
configuration program "enSuite".
The measured gas temperature of the second sensor is
outside the set warning limit values.
The warning limits can be adjusted using the
configuration program "enSuite".
The measured gas pressure of the second sensor is
outside the set warning limit values.
The warning limits can be adjusted using the
configuration program "enSuite".
The remaining battery power is less than six months.
The batteries need to be changed soon.
The measured ambient temperature is outside the set
warning limit values.
The warning limits can be adjusted using the
configuration program "enSuite".
The device is in revision mode.
The internal clock of the volume corrector has not been
adjusted at the factory.
Faults