6.4.6 "Ctrl." register (Control)

This register is used to monitor special device settings. This application is
only intended for service technicians (specialists) or a calibration officer for
putting the device into operation or maintenance.
Display Value
9
St.AL
Administrator lock: State / close
9
Cod.A
Administrator key enter / change
St.PL
Calibration lock: State / close
Menu
Selection of the display menu
Main
Content of the "Main" register
St.AL – Administrator lock: State / close
6.4.6.1
The administrator lock must be opened in order to modify certain
measurement parameters. The administrator lock should be closed when in
normal operating mode.
Display
Meaning
locked
The administrator lock is closed.
open
The administrator lock is open.
Cod.A – Administrator key enter / change
6.4.6.2
By entering the right key (hexadecimal notation) the administrator lock can
be opened. After the administrator lock is open the key can be changed.
The individual characters of the key can take on values from 0 to 9 and
from A to F.
St.PL – Calibration lock: State/close
6.4.6.3
The calibration lock must be opened in order to modify certain
measurement parameters. The calibration lock should be closed when in
normal operating mode.
Display
Meaning
locked
The calibration lock is closed.
open
The calibration lock is open.
In this case, the "P" will also flash in the upper left-hand side
of the display (see chapter 6.3.4 "Meaning of status symbols")
6.4.6.4
Menu - Selection of the display menu
In an as-delivered condition, the display of the EK280 has the following five
9
When using the device with high communication security („High Level Security" see
application manual), the parameter will not be displayed.