Download  Print this page

Kawasaki KZ1300-A1 Quick Reference Manual Page 263

Hide thumbs

Advertisement

MAINTENENCE--ELECTRICAL
Water Tempel'lture Sender Inspection
(K8n
Table K28
Intemel Resistance of
eMeasure
the internal resistance of the
sender
across
the switch terminal and the body at the
temperatures
shown in Table K28. The
internal
resistance of the
sender should change as
shown
in the table.
If
it
does not, replace the
switch.
Table K29
Gauge Resistance
Meter
Connections
One meter lead
~
Yellow lead
Water Temperature Sender
Water Temperature
Resistance
80°C (176°F)
47-570
100°C (212°F)
26-300
Water temperature gauge check
eOpen the headlight housing.
eDisconnect the yellow lead and the 4-pin connector
from the meter assembly
.
-Check the resistance of the meter using an ohmmeter
as shown in Table K29.
If the
resistance
in the test
is found to be less than the proper value, there
is
a
short in the
meter.
No reading
(00)
indicates an open
circu it. I n either case, replace the gauge meter.
A. 4-pin Connector
B. Yellow
Lead
Reading
x 100 Range
The other meter lead
~
Yellow/White lead
54-660
263

Advertisement