OISASSEMBL Y -- CHASSIS
TURN SIGNAL ASSEMBLY
Removal (front, either side):
eRemove the headlight unit (Pg.
139).
eDisconnect the turn signal/running position light leads
(gray and blue) in the headlight housing.
eRemove the headlight housing.
eRemove the mounting nut, lockwasher, and black/
yellow ground lead terminal
,
and pull the front turn
signal from the front fork cover stay.
A.
Ground Lead Terminal
C.
Nut
B. Lockwasher
Installation Notes (front, either side):
1.
Connect the gray lead of the left turn signal to the
green lead of the main wiring harness.
2. Adjust the headlight (Pg. 30)
.
Removal (rear, either side):
eUnlock the seat and swing it open.
eRemove the bolt and flat
washer,
and remove the
document
compartment.
eDisconnect the gray lead of the turn signal.
eRemove the mounting nut,
lockwasher,
flat
washer,
and ground lead terminal
,
and pull off the turn signal
assembly.
Installation Note (rear, either side):
eConnect the gray lead of the left turn signal to the
green lead of the main wiring harness.
METER ASSEMBLY (Speedometer,
Tachometer, Fuel Gauge, Distance Sensor,
Water Temperature Gauge)
Removal:
eRemove the headlight unit
(Pg. 139).
eDisconnect all leads and connectors in the headlight
housing.
eRemove the headlight housing stay bolt and nut under
the housing.
eRemove the housing mounting bolts, nuts, flat washers,
and lockwashers (2 ea), and remove the headlight hous-
ing.
eDisconnect the speedometer and tachometer cables
from the meters.
eRemove the cap nuts
(4),
and remove the cover.
A.
Cap
Nuts
B. Cover
eDisconnect the leads (3) and connectors (3) from the
meter
assembly,
and lift up the meter
assembly.
~ :o~~:ctt~~dem:;e~h:ss:s~e:~I;\ t~a;. t~~
a meter is left upside down or sideways for any length
of time, it will malfunction.
Installation Note:
eBe careful that leads are not pinched between the
mounting plate and the meter
assembly.
Disassembly:
eUnscrew the trip meter reset knob. The knob has a
left hand thread and must be turned clockwise for
removal
.
eRemove the screws (6), and pull the meter assembly
out of the upper
cover.
141

Advertisement

Table of Contents

This manual is also suitable for:

Kz1300-a2

Comments to this Manuals