Page 2
NOTE: THIS HARDWARE, SOFTWARE OR TEST SUITE PRODUCT (“PRODUCT (S)”) AND ITS RELATED DOCUMENTATION ARE PROVIDED BY MELLANOX TECHNOLOGIES “AS -IS” WITH ALL FAULTS OF ANY KIND AND SOLELY FOR THE PURPOSE OF AIDING THE CUSTOMER IN TESTING APPLICATIONS THAT USE THE PRODUCTS IN DESIGNATED SOLUTIONS.
Page 4
Appendix D Installation - Sicherheitshinweise (German) ....46 Appendix E Advertencias de seguridad para la instalación (Spanish) ..49 Appendix F Special Regulations Regarding Finland, Sweden, Denmark, and Norway 53 Rev 1.0 Mellanox Technologies...
UFM®-SDN Appliance. All of these documents can be found on the Mellanox Website. They are available either through the product pages or through the support page with a login and password. Rev 1.0 Mellanox Technologies...
This icon indicates a situation that can potentially cause damage to hardware or soft- ware. BEWARE! This icon indicates a situation that can potentially cause personal injury or damage to hardware or software. Abbreviations Table 3 - Abbreviations Term Description Enhanced Data Rate 4x25 Gb/s = 100 Gb/s Rev 1.0 Mellanox Technologies...
The MAC address of the first management interface (eth0) can be found on the pull-tab. eth0-1 have the next consecutive addresses. Figure 1: Pull Out Tab Location on Appliance Pull out tab Rev 1.0 Mellanox Technologies...
• 2 Hot swap (hard disk drive) HDD drawers Figure 3: UFM-SDN Appliance Front and Rear Side Panels Front side Rear side 2.1.1 System Status LEDs The System Status Indicators are located on the front side panel. Rev 1.0 Mellanox Technologies...
Noncritical error – the appliance is running yet in a reduced state. Atten- a rate of 1Hz) tion required. Flashing Amber (at Warning – impending critical state. Need to attend to this problem before a rate of 1Hz) it becomes fatal. Rev 1.0 Mellanox Technologies...
Figure 6: System Power and On/Off Button and Indicators Power Button w/Integrated LED The primary power supply unit (PS1) is located on the left side of the rear side panel, with PS2 on the right of the PS1. Rev 1.0 Mellanox Technologies...
Your immediate attention is required to avoid fatal errors. 2.1.1.3 Appliance Identifier ID LED and Button This appliance has a combination of button and ID LED identification . The LED can be lit by pushing the button or by using the remote management. Rev 1.0 Mellanox Technologies...
The system is powered on and the driver has spun down Solid Green Power on with no drive activity Activity LED Flashing The system is powered on with drive activity or the drive is spinning Green Rev 1.0 Mellanox Technologies...
For a graceful shutdown of the system (stopping all services, closing all files, flushing all caches etc.) use the relevant CLI command. 2.1.3 NIC Activity LED Indicators The numbered LEDs display the NICs’ activity. Figure 11: NIC Activity LEDs Rev 1.0 Mellanox Technologies...
• 1 RJ-45 serial port • 2 X 100M/1Gb Ethernet connectors • 2 EDR ports • 1 remote management port • 5 USB ports “ ” • System Cold reset button Figure 12: Front Side Interfaces Rev 1.0 Mellanox Technologies...
DHCP configuration for eth0 cannot be used. (There is no DHCP server in the management network). The user is then required to use the serial port to configure a static IP on eth0. NIC#1 Ethernet connector gets connected to Ethernet switches. This switch must be configured to 100M/1G auto-negotiation. Rev 1.0 Mellanox Technologies...
To use the remote management controller with DHCP, the free-range IP allocation must be enabled on the DHCP server. A static IP address for remote management interface can be config- ured via the CLI (“chassis remote-management ip” command). Rev 1.0 Mellanox Technologies...
3.8.1 Installation Safety Warnings For Safety Warnings in French see Section C,“Avertissements de sécurité d’installation (French),” on page 42, for German see Section D,“Installation - Sicherheitshinweise (German),” Rev 1.0 Mellanox Technologies...
Page 22
When this product is mounted or serviced in a rack, special precautions must be taken to ensure that the system remains stable. In general you should fill the rack with equip- ment starting from the bottom to the top. Rev 1.0 Mellanox Technologies...
Page 23
The cord must have a molded on plug cap rated 250 V, 10 A. 13. Do Not Use the Appliance as a Shelf or Work Space Caution: Slide/rail mounted equipment is not to be used as a shelf or a work space. Rev 1.0 Mellanox Technologies...
Page 24
According to the WEEE Directive 2002/96/EC, all waste electrical and electronic equipment (EEE) should be collected separately and not disposed of with regular household waste. Dispose of this product and all of its parts in a responsible and environmentally friendly way. Rev 1.0 Mellanox Technologies...
2. Install the two rails into the rack. Make sure they are at the same level. Make sure they have the correct side to the top. The blue pins go into the rack holes. Figure 15: Left-hand Rail Outside View Collapsed Rev 1.0 Mellanox Technologies...
Figure 18: Inserting Appliance Into Rails 4. Ground the appliance (see “Grounding the Appliance”). 5. Plug in the power cables (see “Power Connections and Initial Power On”). 6. Push the ON/OFF button to start. Figure 19: Turn On Rev 1.0 Mellanox Technologies...
If so, connect a ground wire to one of the casing screws and connect the other end to a valid ground. If you choose not to use the ground screw, make sure that the rack is properly Rev 1.0 Mellanox Technologies...
3. Insert the power supply module into the power supply cage and push all the way until it clicks into place. Do not run the appliance with openings due to missing parts. This may cause overheating due to improper air flow. Rev 1.0 Mellanox Technologies...
4. Slide the replacement HDD in the slot. Continue to push in the HDD in until the latch starts to close. This replacement drive is a blank HDD. 5. Close the latch. 6. Power on the appliance. Rev 1.0 Mellanox Technologies...
HDD, this process might take up to 48 hours to complete. Battery Replacement Mellanox Technologies does not support battery replacement. Customer removal of the UFM cover will void the warranty. Only remove the cover to comply with WEEE directives or to disas- semble for environmentally approved disposal.
According to the WEEE Directive 2002/96/EC, all waste electrical and electronic equipment (EEE) should be collected separately and not disposed of with regular household waste. Dispose of this product and all of its parts in a responsible and environmentally friendly way. Rev 1.0 Mellanox Technologies...
2. Configure a serial terminal program (for example, HyperTerminal, minicom, or Tera Term) on your host PC with the settings described in Table 9 below. Table 9 - Serial Terminal Program Configuration Parameter Setting Baud Rate 115200 Data bits Stop bits Rev 1.0 Mellanox Technologies...
<Enter>. Then confirm the password by re-entering it. Note that password characters are not printed. Step 4: bond0 IP address and masklen? Allows defying IP address for IPoIB bond (bond is [0.0.0.0/0] pre-configured with ib0 & ib1 ports). Rev 1.0 Mellanox Technologies...
7. Admin password (Enter to leave unchanged): (unchanged) 8. bond0 IP address and masklen? [192.168.22.1/24] To change an answer, enter the step number to return to. Otherwise hit <enter> to save changes and exit. Choice: Configuration changes saved. Rev 1.0 Mellanox Technologies...
4.6. Hard drive LED is blink- RAID is rebuilding, wait for this operation to complete (might ing amber take up to 48 hours). Please refer to Section 2.1.1.4 Sec- tion 4.6 for additional information. Rev 1.0 Mellanox Technologies...
Page 37
5. If the appliance does not come on, check the power supplies. 6. If the appliance comes on, use the UFM management software to determine the cause of the shutdown. 7. If the appliance continues to be unresponsive contact Mellanox Support. Rev 1.0 Mellanox Technologies...
• Operating: +10°C to +40°C with the maximum rate of change not to exceed 10°C per Temperature hour • Non-operating:-40° to 70° C Shock and Vibration: Operating Humidity: Shock and Vibration/ ETSI EN 300 019-2-2: 1999-09 90%, non-condensing at 35°C Humidity Storage HDDs Hard Drivers 2 x 1TB HDDs Rev 1.0 Mellanox Technologies...
Page 39
7.0 BA in operating conditions at typical office ambient tempera- Vibration EU: IEC 60068-2-29: Acoustic ture. (23 +/- 2 degrees C) Shocks, Type I / II EU: IEC 60068- 2-32: Fall Test Reliability, Availability and Serviceability Features Hot-Swappable:1+1 Power Supplies N+N Redundant: Swapability / Redundancy Mellanox Technologies Rev 1.0...
EMC Certifications The list of approved certifications per switch in different regions of the world is located on the Mellanox Website at: http://www.mellanox.com/related-docs/user_manuals/Regulatory_and_Compliance_Guide.pdf EMC statements are also in the Regulatory and Compliance Guide. China CCC Warning Statement Rev 1.0 Mellanox Technologies...
Power Supply w/ PSU Side to Connector side airflow for Mellanox® UFM Appli- 00WT199 ance 1U VPI Server HDD 00WT141 Hard Drive for Mellanox® UFM®-SDN Appliance 1U VPI Server Rail Kit 00WT140 Rack installation kit for Mellanox® UFM-SDN Appliance 1U VPI server standard depth racks Mellanox Technologies Rev 1.0...
Les câbles InfiniBand en cuivre sont lourds et ne sont pas flexibles, il faut donc faire très attention en les branchant et en les débranchant des connecteurs. Consultez le fab- ricant des câbles pour connaître les mises en garde et les instructions spéciales. Rev 1.0 Mellanox Technologies...
Page 43
Ce matériel ne doit être installé, remplacé ou entretenu que par du personnel formé et qualifié. 15. Elimination du matériel L’élimination de ce matériel doit s’effectuer dans le respect de toutes les législations et réglementations nationales en vigueur. Mellanox Technologies Rev 1.0...
Page 44
à 3 conducteurs, d’un diamètre de fil minimum de 0,75 mm2, d’une tension nominale de 300 V, avec une gaine isolée en PVC. Le cordon doit avoir une fiche moulée d’une tension nominale de 250 V et d’une intensité nominale de 10 A. Rev 1.0 Mellanox Technologies...
Page 45
Caution: Slide/rail mounted equipment is not to be used as a shelf or a work space. The rails are not intended for sliding the unit away from the rack. It is for permanent instal- lation at final resting place only, not used for service and maintenance. Mellanox Technologies Rev 1.0...
Anschlüsse angebracht bzw. davon getrennt werden. Lesen Sie die speziellen Warnun- gen und Anleitungen des Kabelherstellers. 7. Gafahr des elektrischen Schocks. Gafahr des elektrischen Schocks. Entferrnen des Netzsteckers elnes Netzteils span- nungsfrei. Um alle Einhieten spannungsfrei zu machen sind die Netzstecker aller Netz- teile zu entfernen Rev 1.0 Mellanox Technologies...
Page 47
Für die europäischen Zusammenhang, wählen Sie ein Netzkabel, das international harmonisiert und der Aufschrift "<HAR>", 3 - Leiter, mindestens 0,75 mm2 Draht, bewertet mit 300 V, mit einem PVC-Mantel isoliert. Das Kabel muss eine angespritztem Stecker bewertet bei 250 V, 10 A. " Mellanox Technologies Rev 1.0...
Page 48
Caution: Slide/rail mounted equipment is not to be used as a shelf or a work space. The rails are not intended for sliding the unit away from the rack. It is for permanent instal- lation at final resting place only, not used for service and maintenance. Rev 1.0 Mellanox Technologies...
8 cm (3 pulgadas) alrededor de las aberturas de ventilación. 6. Apilamiento del chasis Los chasis no se deben apilar sobre otros equipos. La caída del chasis podría causar lesiones corporales, así como daños al equipo. Mellanox Technologies Rev 1.0...
Page 50
La eliminación definitiva de este equipo se debe efectuar conforme a todas las leyes y reglamentaciones nacionales. 14. Códigos eléctricos locales y nacionales Este equipo se debe instalar conforme a los códigos eléctricos locales y nacio- nales. Rev 1.0 Mellanox Technologies...
Page 51
UL tipo DP-1 o DP-2. (Nota: cuando residen en circuito no de tipo LPS) Protección contra sobrecargas: Al cableado del edificio se debe incorporar un disposi- tivo de protección contra sobrecargas de circuito derivado, de fácil acceso, con una corriente nominal de 20 A. Mellanox Technologies Rev 1.0...
Page 52
Caution: Slide/rail mounted equipment is not to be used as a shelf or a work space. The rails are not intended for sliding the unit away from the rack. It is for permanent instal- lation at final resting place only, not used for service and maintenance. Rev 1.0 Mellanox Technologies...
• Finland - “Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan” • Norway - “Apparatet må tilkoples jordet stikkontakt” Unit is intended for connection to IT power systems for Norway only. • Sweden “Apparaten skall anslutas till jordat uttag.” Mellanox Technologies Rev 1.0...