Preparations
When installing the installation space must be secured in
consideration of the ventilation and service operation.
• Do not block the ventilation slots at the left side and right
side panels, and vents of fans.
• Leave a space around the unit for ventilation.
• Leave more than 10 cm of space in the rear of the unit to
secure the operation area.
When the unit is installed on the desk or the like, leave at
least 5 cm of space in the left and right sides.
Setting the System
Frequency
This unit is shipped with the system frequency still unset.
Therefore, you need to set the system frequency before
using the unit. (The unit cannot be used unless the system
frequency is set.)
Once it is set, the system frequency is retained even when
the unit is powered off.
To set the system frequency
Use the following procedure.
Rear panel
POWER
POWER
switch
1
TCG
0
0
E X T
- 1 2
- 1 2
- 2 0
- 2 0
TC MODE
P R E S E T
- 3 0
- 3 0
ACCESS
- 4 0
- 4 0
RUN MODE
- 6 0
- 6 0
REC RUN
1
2
3
4
4 CH
16 BIT
3 + 4
NETWORK
T C / V I T C
MPEG HD
SP
1080
60I
V I T C
LOCAL
VITC
COOO1
REM:077
M
D F / N D F
00: 00.00: 00
NDF
REMOTE
P2
LEVEL
CH 1
CH 2
CH 3
CH 4
PHONES
4
Time data display section
22

Setting the System Frequency

2
F1
F2
F3
VAR
MARK1
MENU
F4
CHAPTER
IN
OUT
SUB
THUMB
F5
EXPAND
SET
RESET
CLIP
NAIL
JOG
PAGE DISPLAY
CLIP
ESSENCE
MENU
MARK
MARK2
PREV
PLAY
NEXT
STOP
REC
SHUTTLE
KEY INHI
VARIABLE
REC
PRESET
PB
SHIFT
TOP
F REV
F FWD
END
STANDBY
3
1
Power the unit on.
"SYSTEM SEL" appears in the time data display
section.
2
Press the M/MARK1 button or the m/MARK2 button
to select the system frequency to use.
3
Press the SET button.
"NOW SAVING..." appears in the time data display
section, and the modified setting is saved in the unit's
memory.
"COMPLETE ! !" appears when save processing
finishes.
If you have selected 60I or 30P
When you press the SET button with 60I or 30P
selected in step 2, the following screen appears.
EJECT
Press the M/MARK1 and m/MARK2 buttons to select
"UC" (for areas outside Japan) or "J" (for Japan), then
press the SET button.
2
Chapter
SYSTEM SEL
SYSTEM FREQ:
60I
50I
30P
25P
SELECT : ( )( )KEY
DATA SET :
SET KEY
SYSTEM SEL
SYSTEM FREQ : 601
UC/J SELECT :
UCP
J
SELECT : ( )( )KEY
DATA SET :
SET KEY