Summary of Contents for Tews Technologies TVME200 Series
Page 1
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
The Embedded I/O Company TVME200 4 Slot IndustryPack® VMEbus Carrier Version 1.1 User Manual Issue 1.1.0 February 2009 TEWS TECHNOLOGIES GmbH TEWS TECHNOLOGIES LLC Am Bahnhof 7 Phone: +49-(0)4101-4058-0 9190 Double Diamond Parkway, Phone: +1 (775) 850 5830 25469 Halstenbek, Germany...
Page 3
VME P2 in this document at any time without notice. TEWS TECHNOLOGIES GmbH is not liable for any damage arising out of the application or use of the device described herein.
Page 4
Issue Description Date First Issue November 2001 Value correction chapter “VMEbus P1 connector” and general revision October 2002 Module TVME200-20 added December 2003 Correction “VMEbus P2 Connector” (TVME200-10) December 2003 Function added to switch S3 September 2004 Clarification of Interrupt Mapping November 2004 New address TEWS LLC September 2006...
Table of Contents PRODUCT DESCRIPTION ..................6 TECHNICAL SPECIFICATION................... 7 CONFIGURATION...................... 8 3.1 VME A16 Base Address........................9 3.2 Interrupts ............................11 3.3 VME A24/A32 Memory Enable and Size..................12 3.4 VME A24/A32 Base Address ......................13 IP IRQ AND CONTROL REGISTER................. 15 4.1 IP IRQ Configuration Register .....................15 4.2 IP Control Register........................17 IP STROBE SIGNAL ....................
1 Product Description The TVME200 is a 6U VMEbus Carrier for up to 4 single-size or two double-size IndustryPack (IP) modules used to build modular, flexible and cost effective I/O solutions for applications in process control, medical systems, telecommunication and traffic control. The TVME200 is designed in accordance to VMEbus Specification ANSI/VITA 1-1994 and the IndustryPack Logic Interface Specification ANSI/VITA 4-1995.
3 Configuration Setting 6 rotary switches allows all required configuration of the TVME200. Position of the switches is shown below: Figure 3-1 : Rotary Switch S1 – S6 Step Rotary Switch Function Default Value S1 / S2 VME A16 Base Address 0x6000 Interrupt Mapping VIPC6xx compatible...
3.1 VME A16 Base Address The VME A16 Base Address of the TVME200 is set by rotary switch S1 and S2. Rotary switch S1 sets A[15:12] of the VME A16 Base Address. Rotary switch S2 sets A[11:10] of the VME A16 Base Address. Figure 3-3 : VME A16 Base Address The default value for the VME A16 Base Address is 0x6000 (S1=6, S2=0).
VME A16 Base Address Description Default + 0x0000 I/O Space IP A 0x6000 + 0x0080 ID Space IP A 0x6080 + 0x00C0 IRQ and Control Register IP A 0x60C0 + 0x0100 I/O Space IP B 0x6100 + 0x0180 ID Space IP B 0x6180 + 0x01C0 IRQ and Control Register IP B...
3.2 Interrupts Each IndustryPack can generate interrupts on two interrupt request lines (INT0 and INT1). The VMEbus offers seven interrupt request level. IRQ7 has the highest priority, IRQ1 has the lowest priority. IP interrupt requests can be mapped to any of the 7 VME interrupt request levels. Interrupt routing from the IP slots to the VME IRQs can be done by selection of predefined sets with a rotary switch or programmable by software if S3 is in the range of “0”...
3.3 VME A24/A32 Memory Enable and Size If VME memory space is not required, switch S4 to “0” (VME A24/A32 memory disabled). Figure 3-8 : VME A24/A32 Memory Enable and Size IndustryPack Memory is mapped into the VME A24 or VME A32 memory space. In VME A24 memory space, the memory size can be configured from 32 Kbytes to 2 Mbyte memory per IP slot.
3.4 VME A24/A32 Base Address The memory space of IndustryPacks is mapped in the VME A24 or VME A32 space. The memory base address for VME A24 or VME A32 is both set with the switches S5 and S6. Figure 3-10: VME A24/A32 Base Address If memory space is located in VME A24, S5 represents A[23:20], and S6 represents A[19:16].
4 IP IRQ and Control Register If switch S3 is in the range of “0” to “7”, the TVME200 provides a set of two registers for each IP: The IP IRQ Configuration Register and the IP Control Register. Setting switch S3 to a value of “8” to “F” disables the IP IRQ Register and the IP Control Register. The address range of the IP IRQ and Control Register from “VME A16 Base Address”...
IP C IRQ Configuration Register VME A16 Base Address + 0x02C1 Symbol Description Access Reset Value VME IRQ Level Depends on S3 jumper 000 = interrupt is disabled IP C, INT1 setting [6:4] 001 to 111 = VMEbus IRQ levels IRQ1 to IRQ7 VME IRQ Level Depends on...
4.2 IP Control Register Four IP Control Registers are located in the VMEbus A16 space. Switch S3 must be in the range of “0” to “7” to access the IP Control Register. IP A Control Register VME A16 Base Address + 0x00C3 Symbol Description Access...
IP C Control Register VME A16 Base Address + 0x02C3 Symbol Description Access Reset Value IP C, Reset 1 = reset is initiated Remains ‘1’, until the IP reset has been completed and is then set to ‘0’ by the on board logic. It can be read to verify the status of the reset.
5 IP Strobe Signal The IP strobe signal is an uncommitted line of the IP logic interface, which may be used as an optional input to or output from an IP module. It is reserved for a digital strobe or clock signal related to the functionality of the IP.
6 Installation of IndustryPacks Before installing an IndustryPack, be sure that the power supply for the TVME200 is turned off. The component is an Electrostatic Sensitive Device (ESD). Use an anti-static mat connected to a wristband when handling or installing the components. Installing IndustryPacks on the TVME200 is done by simply snapping them into one of the four IP slots.
7 Front Panel Indicators 7.1 ACK and Power LEDs For a quick visual inspection the TVME200 offers a total of 10 LEDs in the front panel. Each IndustryPack has its own “ACK” LED, which is lit for about 200ms whenever an access to the corresponding IP happens.
8 TVME200-20 The TVME200-20 is a special version of the TVME200-10 that provides additional back I/O for ‘IP C’ and ‘IP D’ like the SBS VIPC61x. If you do not need the back I/O option, it is recommended that you use the TVME200-10 because of better I/O isolation and signal integrity.
9 Pin Assignment 9.1 IP Connectors The table below shows the complete IP J1 logic interface pin assignments. Some of these signals are not used on the TVME200. Pin # Signal Pin # Signal Pin # Signal Pin # Signal Reset# R/W# IDSel#...
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...