2. Commissioning
2.2.4 Application example for the parameterisation
1
Input for
1st sensor
(with default
parameterisation)
2
Parameterised
input for 2nd
sensor (see text)
Fig. 2/13: Application example for parameterisation of input debounce time and signal
extension time on the 2nd sensor
Festo P.BE−CPX−PN IO−EN en 0710NH
Î
In the above application, packets are transported on a
fast−moving conveyor belt.
The input for the 2nd sensor is parameterised as follows for
improvement of the signal recording and processing:
Reduction of the input debounce time from 3 ms (factory
setting) to 0.1 ms: Recording shorter signals is possible.
This parameter is set for the complete module.
Signal extension time set to 50 ms: Reliable recording of
the signals by the controller.
The value of this parameter is set for the complete mod
ule, however must be activated/deactivated separately
for each input channel.
1
2
1st sensor
2nd sensor
Î Î
2−39