HYDRAULIC CONNECTION TO THE SYSTEM

OK
Do not install any tee or tap between pump and BEST CONTROL unit.
Prepare all threads with Teflon tape only.
Do not over thighten water connections, especially when installing with metal
couplings. Damage to BEST CONTROL may result.
Open the electronic box cover by removing
the six screws from the cover.
Line voltage and pump wires to the BEST CONTROL should be supplied through "liquid-
tight" nonmetallic conduit fittings rated "NEMA 12" or "UL type 12" to achieve NEMA Type
12 enclosure rating.
Failure to install unit without use of liquid tight conduit voids warranty!
Always install BEST CONTROL with flow arrows in the
vertical position.
Electronic box must be level.
NO

CONDUIT CONNECTIONS

- 4 -

Hide quick links: