Diagram Reference Legend - Lennox Baltic BCK 020 Installation, Operating And Maintenance

Hide thumbs Also See for Baltic BCK 020:
Table of Contents

Advertisement

ELECTRICAL DATA - wiring diagrams

DIAGRAM REFERENCE LEGEND

-A1
Soft starter
-B2
Smoke detection head
-B4
Gas manifold ionisation probe
-B6
Gas manifold ignition electrode
-B13
Dirty air filter pressure switch / air flow rate
-B14
Hot water battery antifreeze thermostat
-B16
Fire thermostat
-B17
Gas manifold smoke minimum gas pressure switch
-B19
Blower fan motor -MS1-MS2 stoptherme
-B21
Gas manifold extraction air pressure switch
-B23-B24
Extraction fan motor -ME1-ME2 stoptherme
-B25-B26
Electric battery -E1-E2 safety klixon
-B29
Gas manifold air flow rate safety klixon
-B32
Gas manifold flashback safety klixon
-B41-B42
Compressor -MG1-MG2 high pressure safety switch
-B45
Gas manifold 1 / gas manifold 2 regulation klixon
-B51-B52
Compressor -MG1-MG2 low pressure safety switch
-B61-B62
Compressor -MG1-MG2 high pressure control switch
-B71-B72
Condenser -MC1-MC2 fan motor stoptherme
-B81-B82
Scroll compressor -MG1-MG2 protection module
-BE50
Climatic 50 extension board
-BG10
CO2 sensor
-BH10
Regulation hygrometry probe
-BH11
External hygrometry probe
-BT10
Regulation temperature probe
-BT11
External temperature probe
-BT12
Blower temperature probe
-BT17
Return air sensor
-BT91-BT92 Defrost temperature sensor compressor 1-2
-BM50
Climatic 50
BX 50
Multiplexer Climatic 50
-C1-C2-C3-C4 Condensator
-E1-E2
Heater -E1-E2
-E11
Smoke detector printed circuit
-E14
Burner control box
-EF47
Gaz burner printed circuit
-F1
Secondary circuit -T1 128VA / 24V protection fuse
-KA31
Gas burner fault relay
-KE1-KE2
Heater -E1-E2 contactor
-KM1
Blower fan motor -MS1-MS2 contactor
-KM5
Extraction fan motor -ME1-ME2 contactor
-KM9-KM10 Condenser 1 / condenser 2 fan motor contactor
-KM11-KM12 Compressor -MG1-MG2 contactor
-MC1-MC2
Condenser -MC1-MC2 fan motor
-ME1-ME2
Extraction fan motor -ME1-ME2 contactor
-MG1-MG2 Compressor -MG1-MG2 contactor
-MR1
Economiser damper motor
-MR3
Fresh air damper motor
-MS1
Blower fan motor -MS1-MS2
-Q1
Blower fan motor -MS1-MS2 protection
-Q5
Extraction fan motor -ME1-ME2 protection
-Q9
Condenser -MC1-MC2 fan motor protection
-Q11-Q12
Compressor -MG1-MG2 protection
-QF1
Primary circuit protection -T1
-QF2
Primary circuit protection -T3
-QF3
Secondary circuit protection -T3
-QG
Main switch
-QE1-QE2
Heater -E1-E2 protection
-T1
Control circuit transformer 400v / 24v
-T3
Burner power supply transformer 400 / 230v
-TCB
control thermostat
UF
Cooling unit
UT
Air treatment unit
-V1
Electric heater static contactor
-YV2
Hot water 3-way valve
-YV11-YV12 Compressor -MG1-MG2 cycle reversing valve
-YV31
Burner gas solenoid valve
-YV41
Gas manifold safety solenoid valve
-YV51
Gas manifold main solenoid valve
-Z*
Capacity resistance circuit
IOM / ROOFTOP BALTIC Series - 0704-E Page 127