LONWORKS MENU TREE - CONTROL variables
LONWORKS
Settings and Readings
R/W
L
R/W
L
R/W
L
R/W
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R/W
1 = 1 s
R/W
10 = 1.0°c
R/W
10 = 1.0°c
R/W
1 = 1%
R/W
10 = 1.0°c
R/W
10 = 1.0°c
R/W
1 = 1%
R/W
1 = 1%
R/W
1 = 1h
R/W
1 = 1m
R/W
1 = 1
R/W
1 = 1
R
1 = 1
R
10 = 1.0°c
R
10 = 1.0°c
R
10 = 1.0°c
R
10 = 1.0%
R
10 = 1.0 g/Kg
R
10 = 1.0%
R
10 = 1.0 g/Kg
R
1 = 1%
R
1 = 1%
R
1 = 1%
R
1 = 1%
[On / Off] Unit
[Reset] Discharges the safety measures of the unit
[BMS] Activation of the Inoccupation mode [Off] occupation mode - [On] inoccupation mode
[Clock] [OFF] read hour & minute [ON] write hour & minute
[Alarm] General
[On/Off] Fan, Blower
[On/Off] Compressor, 1
[On/Off] Compressor, Heat pump, 1
[On/Off] Compressor, 2
[On/Off] Compressor, Heat pump, 2
[On/Off] Compressor, 3
[On/Off] Compressor, Heat pump, 3
[On/Off] Compressor, 4
[On/Off] Compressor, Heat pump, 4
[On/Off] Gas, Burner, 1
[On/Off] Gas, Burner, 2
[On/Off] Gas, Burner, High power, 1
[On/Off] Electrical heaters, 1
[On/Off] Electrical heaters, 2
[ BMS ] Activation of the control by a computer or an automat -
mode BMS is activated if this value is different from zero,
This value is decreased every second
[Occupation][Room SP] Required maximum room temperature in °C.
Cooling set point
[Occupation][Room SP] Required minimum room temperature in °C.
Heating set point
[Room SP] Required room minimum fresh air rate in %.
Middle of the dead zone
[Inoccupation][Room SP] Required maximum room temperature in °C.
Cooling set point
[Inoccupation][Room SP] Required minimum room temperature in °C.
Heating set point
[Humidity] Desired Maximum relative humidity in Room (in %). –
Dehumidification set point.
[Humidity] Desired Minimum relative humidity in Room (in %). –
Humidification set point.
[Clock] Hour
[Clock] Minute
[Clock] Day of the month
[Clock] Month
[Alarm] Code Error
[Temperature] Room
[Temperature] Outdoor
[Temperature] Supply
[Relative Humidity] Outdoor
[Absolute Humidity] Outdoor
[Relative Humidity] Room
[Absolute Humidity] Room
[% of opening] Register of fresh air
[% of opening] Valve gas
[% of opening] Electrical heaters (Triac)
[% of opening] Hot water coil
IOM / ROOFTOP BALTIC Series - 0704-E Page 115
DS50
3111
3112
3933
...
1000
2315
2516
2517
2526
2527
2536
2537
2546
2547
2615
2616
2617
2625
2626
DS50
3932
3322
(BMS)
3323
(BMS)
3312
(BMS)
3322
(Uno)
3323
(Uno)
3341
(BMS)
3342
(BMS)
3121
3122
3123
3124
1000
2112
2111
2113
2121
2123
2122
2124
2413
2618
2627
2633