Figure 34 Test For Actuator Operation - Honeywell HercuLine 10260S Installation, Operation And Maintenance Manual

Smart actuator
Table of Contents

Advertisement

Test for Actuator Operation
Yes
All LEDs and
display segments
light?
Yes
E
Revision 5
10260S HercuLine® Actuator Installation, Operation and Maintenance Manual
7/07
Yes
Observe self test.
Do all diagnostics pass?
RAMTST PASS
SEETST PASS
CALTST PASS
CFGTST PASS
No
Replace display
assembly

Figure 34 Test for Actuator Operation

9. Troubleshooting - Troubleshooting Procedures
A
Cycle power
to actuator.
No
Does display
light up?
No
B
Move handwheel
on actuator 2 or
3 turns.
No
Does motor
reposition
itself?
Yes
Replace display
assembly
E
99

Advertisement

Table of Contents
loading

Table of Contents