Detailed display
Display example
(Supplementary Explanation)
(1) When the [PAUSE] key is released within 3 seconds while the printer is paused, the [PAUSE] key is
invalid.
(2) To program the threshold, 1.5 pieces or more label shall be fed. (If the label feed amount is insufficient,
the threshold may not be properly programmed. In this case, the threshold setting is required again.)
(3) While the head is lifted, the [PAUSE] key is invalid even if the [PAUSE] key is held down for 3 seconds or
more.
(4) When the proper print position is not obtained even after threshold setting, the sensor may be improperly
adjusted. In this case, readjust the sensor in system mode, and program the threshold.
When the backing paper of the label is too thick, the transmissive sensor needs to be readjusted.
In addition, make sure that "3: Transmissive sensor (when using the preprinted label)" or "4: Reflective
sensor (when using a manual threshold value)" is selected for sensor type of the Feed Command and
the Issue Command.
(5) Paper end and ribbon end are not detectable during the threshold setting. (The setting continues as long
as the [PAUSE] key is held down even if the printer runs short of media or ribbon.)
(6) The detailed display is shown when the [RIGHT] key is pressed while the result is displayed. The
measured sensor level and the currently programmed threshold fine adjustment value can be checked.
Fine adjustment value = Peak voltage – Threshold voltage
(7) Pressing the [LEFT] key returns the detailed display to the result display. Pressing the [RIGHT] key
causes the display to go to threshold fine adjustment screen. This is the same menu with the threshold
fine adjustment menu in section 8.5.9 (Reflective sensor) or 8.5.10 (Transmissive sensor).
(8) After setting the threshold fine adjustment value, the screen returns to the result display.
(9) While the result of fine adjusted threshold setting is shown, pressing the [LEFT] key returns the display to
the threshold fine adjustment screen and pressing the [RIGHT] key goes to the detailed display.
(10) During threshold setting, the media is fed at the same speed with that for the previous issue.
(11) Whether the threshold setting succeeded or not can be checked with either of the following methods.
Media feed with the [FEED] key
1. While the judgment result is displayed, press the [FEED] key to terminate the threshold setting.
→ The printer is placed in the pause state.
2. Press the [RESTART] key to clear the pause state.
→ The printer is placed in the online state.
3. Hold down the [MODE] key.
→ The printer enters the user system mode.
4. Select "<2>PARAMETER SET", "Software Set", then "THRESHOLD SELECT" with the [UP], [DOWN]
and [ENTER] keys.
5. Select the applicable media sensor type ("REFLECT" or "TRANS.") and press the [ENTER] key.
→ The selected sensor type display is shown.
6. Select "MANUAL SET", press the [ENTER] key, then [MODE] key.
→ User system mode menu is displayed.
Displayed item
Sensor type
Peak value
Threshold voltage
Baseline voltage
Key operation guid
e
Explanation
The calibration result and the threshold voltage
are displayed.
Pressing the [RIGHT] key enables setting a
threshold fine adjustment value.
Pressing the [LEFT] key returns the display to the
calibration result display.