Maximum number of continuous flashes
The maximum number of continuous flashes during multiple flash photography is
limited by the charge in the battery. Use the following values as a guide.
With alkaline batteries
Power level
100 90 80 70 60 50 40 30 20 10
1/8
4
4
1/16
8
8
1/32
14 14 14 14 14 18 18 20 20 25 35 35 40 50 50 50 50 100 100*
With nickel-metal hydride batteries (When using 2500 mAh)
Power level
100 90 80 70 60 50 40 30 20 10
1/8
4
4
1/16
8
8
1/32
15 17 17 17 18 18 18 20 25 50 60 70 70 70 70 100* 100* 100* 100*
• The maximum number of flashes varies with the type of battery and its
condition. If an External Battery Adaptor FA-EB1AM (optional) is used, the
maximum number of flashes increases beyond the values given above.
Flash frequency (Hz)
4
4
4
4
4
8
8
8
8
8
Flash frequency (Hz)
4
4
4
4
5
8
8
8
9
10 10 10 15 15 15 20 20 30 50 100 100* 100*
9
8
4
4
5
5
6
8
8
10 15 15 15 20 20 20 35 40 100
9
8
5
5
7
7
7
7
6
5
4
3
6
6
7
8
10 14 14