Technical Data For Output Expansion 3Sk1213 - Siemens SIRIUS 3SK1 Manual

Industrial controls, safety engineering, safety relays
Hide thumbs Also See for SIRIUS 3SK1:
Table of Contents

Advertisement

13.3.1.2

Technical data for output expansion 3SK1213

Insulation voltage rated value
Resistance against shock
Number of sensor inputs 1-channel
or 2-channel
Type of the safety-related wiring of
the inputs
Product feature transverse contact-
secure
Safety Integrity Level (SIL)
according to IEC 61508
SIL claim limit (for a subsystem)
according to EN 62061
Performance level (PL) according to
ISO 13849-1
Category according to ISO 13849-1
T1 value for proof test interval or
service life according to IEC 61508
Safety device type according to
IEC 61508-2
Number of outputs as contact-
affected switching element
as NC contact for reporting
function instantaneous switching
as NO contact for reporting
function instantaneous switching
as NC contact for reporting
function delayed switching
as NO contact for reporting
function delayed switching
as NC contact safety-related
instantaneous switching
as NO contact safety-related
instantaneous switching
as NC contact safety-related
delayed switching
as NO contact safety-related
delayed switching
Stop category according to
DIN EN 60204-1
Design of the input start input
Design of the electrical connection
jumper socket
3SK1 safety relays
Manual, 04/2013, A5E02526190021A/RS-AA/01
3SK1213-.AB..
V
300
5 g / 10 ms
SIL3
3
e
4
a
20
Type A
0
0
0
0
0
3
0
0
0
No
13.3 Expansion modules
3SK1213-.AJ..
3SK1213-.AL..
Technical data
233