I/O combined module

NZ2GN2S1-32DT DC input/transistor output module
Item
Input specifications
Number of input points
Rated input voltage
Rated input current
Maximum number of simultaneous input points
ON voltage/ON current
OFF voltage/OFF current
Input resistance
OFF → ON
Input response time
ON → OFF
Wiring method for common
Output specifications
Number of output points
Rated load voltage
Max. load current
Maximum inrush current
Leakage current at OFF
Max. voltage drop at ON
OFF → ON
Output response time
ON → OFF
Surge suppressor
External power supply for
Voltage
output part
Current
Protection function
Overload protection
function
Overheat protection
function
Wiring method for common
Common specifications
Station type
Authentication Class
Withstand voltage
Insulation resistance
*2
Noise immunity
Protection degree
External interface
Communication part
Module power supply part
I/O part
Applicable wire size
For power supply
For I/O
Applicable solderless
Terminal block for module
*4
terminal
power supply and FG
I/O terminal block
Cyclic transmission
RX/RY points
RWr/RWw points
Module power supply
Voltage
Current
NZ2GN2S1-32DT
16 points
24VDC (ripple rate: 5% or less) (Allowable voltage range: 20.4 to 28.8VDC)
6.0mA TYP. (for 24VDC)
100%
11VDC or more/4mA or more
5VDC or less/1.5mA or less
3.3kΩ
*1
0ms
/0.2ms/1ms/1.5ms/5ms/10ms/20ms/70ms
(Factory default: 1ms)
16 points/common (Common terminal: terminal number 33) (1-wire, spring clamp terminal block type)
Positive common type
16 points
24VDC (ripple rate: 5% or less) (Allowable voltage range: 20.4 to 28.8VDC)
0.5A/point, 4A/common
Current is limited by the overload protection function.
0.1mA or less
0.3VDC (TYP.) 0.5A, 0.6VDC (MAX.) 0.5A
0.1ms or less
0.8ms or less (resistive load)
Zener diode
24VDC (ripple rate: 5% or less) (Allowable voltage range: 20.4 to 28.8VDC)
25mA or less (TYP. 24VDC per common) External load current is not included.
Limited current when detecting overcurrent: 1.5 to 3.5A/point
Activated to each point.
Activated to each point.
16 points/common (Common terminal: terminal number 34) (1-wire, spring clamp terminal block type)
Sink type
Remote station
Authentication Class B
510VAC for 1 minute between all DC external terminals and ground
10MΩ or higher between all DC external terminals and ground (500VDC insulation resistance tester)
Noise voltage 500Vp-p, noise width 1μs, noise frequency 25 to 60Hz (DC type noise simulator
condition)
IP2X
RJ45 connector
Terminal block for module power supply and FG (2-piece spring clamp terminal block)
2-piece spring clamp terminal block
Stranded wire: 0.3 to 1.5 (22 to 16 AWG), terminal slot size: 2.4mm × 1.5mm
Stranded wire: 0.3 to 1.5 (22 to 16 AWG)
Page 65 Applicable solderless terminal
Page 69 Applicable solderless terminal
32 points
4 points
24VDC (ripple rate: 5% or less) (Allowable voltage range: 20.4 to 28.8VDC)
110mA or less (24VDC, all points ON)
*3
3 SPECIFICATIONS
3.3 Performance Specifications
3
35