Table 5-2 Constants For Calculating The Slot Time For Dp-Standard (Redundant Optical Ring) - Siemens OLM/P11 V4.0 Operating Instructions Manual

Simatic net profibus optical link module
Table of Contents

Advertisement

Installation and Maintenance
5.10 Configuration
Data rate
a
5
12 Mbps
1651
1
6 Mbps
951
1
3 Mbps
551
1
1.5 Mbps
351
500 Kbps
251
187.5 Kbps
171
93.75 Kbps
171
45.45 Kbps
851
19.2 Kbps
171
9.6 Kbps
171
Table 5-2
Constants for calculating the slot time
for DP-standard (redundant optical ring)
Data rate
a
1
12 Mbps
1651
1
6 Mbps
951
1
3 Mbps
551
1
1.5 Mbps
2011
500 Kbps
771
187.5 Kbps
771
93.75 Kbps
451
45.45 Kbps
851
19.2 Kbps
181
9.6 Kbps
171
Table 5-3
Constants for calculating the slot time for
DP/FMS ("universal") and DP with S5 95U (redundant optical ring)
The slot time calculation only takes into account the optical network and the
connection of bus nodes to the OLM via a RS-485 bus segment each with a
maximum length of 20 m. Longer RS-485 bus segments are included in the
calculation by adding them to the length of the fiber-optic cables.
Note:
If the value of the slot time is configured too low, this can lead to malfunctions and
error messages on the OLM. The system LED flashes red/green.
5
With OLM/G11-1300 and OLM/G12-1300, minimum slot times must be maintained according to the following table at data
rates of 12 Mbps, 6 Mbps, 3 Mbps and 1.5 Mbps:
Data rate
Minimum slot time
12 Mbps
3800 t
Bit
6 Mbps
2000 t
Bit
3 Mbps
1000 t
Bit
1.5 Mbps
530 t
Bit
If the calculated slot time is shorter than the minimum slot time, use the minimum slot time from the table above as the
configured slot time.
SIMATIC NET PROFIBUS, Optical Link Module
Operating Instructions, 07/2008, A2B00065774O, Edition V1.5
b
c
240
28
120
24
60
24
30
24
10
24
3.75
24
1.875
24
0,909
24
0,384
24
0,192
24
b
c
240
28
120
24
60
24
30
24
10
24
3.75
24
1.875
24
0.909
24
0.384
24
0.192
24
43