Siemens SINUMERIK 802D sl Programming Manual page 229

Iso milling
Hide thumbs Also See for SINUMERIK 802D sl:
Table of Contents

Advertisement

04.07
20152
MD number
Default setting:
Changes effective after Reset
Data type: BYTE
Meaning:
This MD cannot SINUMERIK 802D sl.
20154
MD number
Default setting: - -
Changes effective after Power On
Data type: BYTE
Meaning:
This MD cannot SINUMERIK 802D sl.
© Siemens AG 2007 All rights reserved
SINUMERIK 802D sl/840D/840D sl/840Di/840Di sl/810D ISO Milling (PGM) - - 04.07 Edition
GCODE_RESET_MODE
Reset response in the G groups
Minimum input limit: 0
Protection level: 2/7
This machine data is only evaluated if bit 0 is set in $MC_RESET_MODE_MASK. For
every entry in machine data $MN_GCODE_RESET_VALUES (and thus for every G group)
this MD defines whether the setting corresponding to $MC_GCODE_RESET_VALUES will
be resumed upon the occurrence of a reset/parts program end (MD = 0), or if the setting
valid at that moment will be retained (MD = 1).
Example:
In this case whenever there is a reset/parts program end, the initial setting for the sixth G
group (current plane) will be read from machine data $MC_GCODE_RESET_VALUES:
$MC_GCODE_RESET_VALUE(5)=1;
$MC_GCODE_RESET_MODE(5)=0;
If it is required that the current setting for the sixth G group (current plane) be retained in
the event of a reset/parts program end, the setting is as follows:
$MC_GCODE_RESET_VALUE(5)=1;
$MC_GCODE_RESET_MODE(5)=1;
EXTERN_GCODE_RESET_VALUES[n]: 0, ..., 30
Defines the G codes which are activated on startup if the NC channel is not running in
Siemens mode.
Minimum input limit: - -
Protection level: 2/2
The following external programming languages are possible:
- - ISO dialect milling
- - ISO dialect turning
The G group classification to be used is specified in the current SINUMERIK documenta- -
tion.
The following groups can be defined within MD EXTERN_GCODE_RESET_VALUES:
ISO dialect M:
G code group 2:
G code group 3:
G code group 5:
G code group 6:
G code group 13:
G code group 14:
ISO dialect T:
G code group 2:
G code group 3:
G code group 5:
G code group 6:
G code group 16:
Machine and Setting Data
D.2 Channel-specific machine data
Maximum input limit: 1
Unit: - -
Applies with effect from SW version:
Reset value of sixth G group is M17
Initial setting for sixth G group after a
reset/parts program end is as in
$MC_GCODE_RESET_VALUES(5)
Reset value of sixth G group is M17
Current setting for the sixth G group
is retained even after a reset/part
program end
Maximum input - -
Unit: - -
Applies with effect from SW version: 5
G17/G18/G19
G90/G91
G94/G95
G20/G21
G96/G97
G54- -G59
G96/G97
G90/G91
G94/G95
G20/G21
G17/G18/G19
D-229

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents