Siemens SINUMERIK 802D sl Programming Manual page 155

Iso milling
Hide thumbs Also See for SINUMERIK 802D sl:
Table of Contents

Advertisement

04.07
Simple call up (G65)
Format
G65 P_ L_ ;
By specifying "G65 P · · · L · · · <argument specification>; ", the macroprogram
which is assigned the program number specified with P is called up and executed L
times.
If it is necessary to pass arguments to the called up macroprogram, these argu-
ments can be specified in this block.
Table 4-8
Address
P
L
System variables for the addresses I, J, K
Because addresses I, J, and K can be programmed up to ten times in a block by
macro call, an array index must be used to access the system variables for these
addresses. The syntax for these three system variables is then $C_I[..], $C_J[..],
$C_K[..]. The values are stored in the array in the order programmed. The number
of addresses I, J, K programmed in the block is stored in variables $C_I_NUM,
$C_J_NUM, $C_K_NUM.
The passed parameters I, J, K for macro calls are treated as one block, even if
individual addresses are not programmed. If a parameter is programmed again or a
following parameter has been programmed with reference to the sequence I, J, K,
it belongs to the next block.
To recognize the programming sequence in ISO mode, system variables
$C_I_ORDER, $C_J_ORDER, $C_K_ORDER are set. These are identical arrays
to $C_I, $C_K and contain the associated number of parameters.
Note
The transfer parameters can only be read in the subroutine.
Example:
N5 I10 J10 K30 J22 K55 I44 K33
set1
$C_I_NUM=2
$C_I[0]=10
$C_I[1]=44
$C_I_ORDER[0]=1
© Siemens AG 2007 All rights reserved
SINUMERIK 802D sl/840D/840D sl/840Di/840Di sl/810D ISO Milling (PGM) -- 04.07 Edition
P and L commands
Program number
Number of repetitions
set2
set3
Enhanced Level Commands
Description
5 digits
9 digits
4.10 Macroprograms
Number of digits
4-155