Ambient conditions

Ambient temperature
Remark
Transport and storage tem-
perature
Humidity class
Mechanical stressing during
operation
SITOP PSU8200 3ph
Manual, 11.2014, C98130-A7638-A1-2-7629
6EP3436-8SB00-0AY0 (24 V/20 A)
-25°...+70° C with natural convection
In the range -25 ... 0 °C continuous starting at a rated input voltage +/-10 % is possible.
The specified properties (see Technical data (Page 29)) are only guaranteed in the
0 ...+70 °C range.
Tested according to:
EN 60068-2-1 cold
EN 60068-2-2 dry heat
EN 60068-2-78 humid heat, constant
EN 60068-2-14 temperature change
-40 ... +85° C
Tests (packed for shipping) according to:
EN 60068-2-1 cold
EN 60068-2-2 dry heat
EN 60068-2-30 humid heat, cyclic
Climatic class 3K3 according to EN 60721,
without condensation
Tested according to:
EN 60068-2-6 vibration, test Fc:
7 mm deflection in the range
5 ... 8.4 Hz
2 g acceleration in the range
8.4 ... 150 Hz
EN 60068-2-27 shock, test Ea:
acceleration 150 m/s
, test duration
2
11 ms
6EP1437-3BA10 (24 V / 40 A)
Climatic class 3K3 according to EN 60721,
without condensation
Tested according to:
EN 60068-2-6 vibration, test Fc:
0.075 mm deflection in the range
10 ... 58 Hz
1 g acceleration in the range
58 ... 150 Hz
EN 60068-2-27 shock, test Ea:
acceleration 150 m/s
, test duration
2
11 ms
8
43