Download Print this page

American Standard AUD2B060AFV32A Installer's Manual page 30

Variable speed, 2-stage, 80% upflow/horizontal gas-fired furnaces, fan assisted combustion system with whole house air cleaner

Advertisement

After installation has been completed, it is recommended that the Furnace be checked against the following
checklist.
1. Make sure power is "OFF" at power disconnect
switch ................................................................. [ ]
2. Check all field wiring for tight connections. See
that grounding of unit is in accord with code ... [ ]
3. Make sure unit suspension (if used) is secure and
that there are no tools or loose debris in, around or
on top of the unit ............................................... [ ]
4. Check all duct outlets; they must be open and unre-
stricted ............................................................... [ ]
5. Check drain lines and be sure all joints are tight ..
........................................................................... [ ]
6. Make sure secondary drain pan is installed ..... [ ]
7. Check power supply for correct requirements per
unit nameplate .................................................. [ ]
8. Energize the system and carefully observe its op-
eration; make any necessary adjustment ........ [ ]
9. Adjust ozone setting, if needed ......................... [ ]
10. Instruct owner on proper operating procedure and
leave Use and Care Manual with owner .......... [ ]
Trane
6200 Troup Highway
Tyler, TX 75707
For more information contact
your local dealer (distributor)
CHECKOUT PROCEDURES
11. Check the Whole House Air Cleaner power output
RISK OF ELECTRICAL SHOCK
ELECTRICAL POWER IS PRESENT FOR THE
NEXT 2 STEPS.
PERFORMED ONLY BY QUALIFIED PERSON-
NEL.
FAILURE TO FOLLOW THIS WARNING COULD
RESULT IN PERSONAL INJURY, ELECTRICAL
SHOCK, OR DEATH.
Since the manufacturer has a policy of continuous product and product data improvement, it reserves the
right to change design and specifications without notice.
by the Green LED illumination. If the LED is on,
this indicates High Voltage output to the air
cleaner. ........................................................... [ ]
a) Turn the Comfort Control to fan only.
b) Remove blower door panel.
WARNING
!
THESE STEPS SHOULD BE
c)
Depress blower door switch.
d) Verify with Fan running that green LED is il-
luminated.
e) Release Blower Door Switch and put Blower
Door back on.
f)
Turn Comfort Control to desired position.
03/08

Advertisement

loading