INTELLIGUARD 9000
The Output Points table defines location, address and function for each output point.
An output can activate a bell, siren, light or other such device. The following fields
define all output points:
No.
Output point number of the I9000.
Ref.
Reference number of the device output location.
Out.
Output number assigned to the device.
Func. Relay function number that activates this output.
The following buttons affect the Output Points table.
Insert
Inserts one line, moving succeeding outputs back one.
Delete
Erases the entry but leaves the line available for future use.
Remove
Removes the line, moving outputs forward one.
OK
Accepts any changes and exits the table.
2. Type in the output device reference number.
3. Press Tab to move to the next field.
4. Type in the applicable output number of the device.
5. Tab to move to the next field.
6. Type in the applicable relay function number.
7. Tab to move to the next output number.
8. Repeat steps 2 through 7 for each output point.
9. Tab to the next field.
10. Click OK to accept the field entries.
11. Click File to display the File pull-down menu.
12. Click Save to save the changes.