5. INSTALLATION INSTRUCTIONS

5.1 Exhausting hot air

In the COOLING Mode the appliance
must be placed close to a window or
opening so that the warm exhaust air
can be ducted outside. First position unit
on a flat floor and make sure there's a
minimum of 30cm clearance around the
unit, and is within the vicinity of a single
circuit outlet power source.
1. Extend either side of the hose (Fig. 3).
Fig. 3
2. Slide the adaptor A into the exchange
hole of the unit as shown on Fig. 4.
Fig. 4
3. Install the window kit on the window
and slide the adaptor B into the
window slider kit and seal. (Fig. 5 & 6)
Window Slider Kit
Minimum: 56cm
Maxmum: 112cm
Refer to "5.2 Installation in
a casement window" about
how to install the window kit.
The hose can be extended from
its original length of 38cm up to
150cm, but it is the best to keep
the length to minimum required.
Also make sure that the hose
does not have any sharp bends
or sags. (Fig. 7)
5.2 Installation in a casement
window
1. Open the window sash and lift the
locking lever of the window slider
kit (Fig. 9)
Fig. 5
B: Locking lever
ENGLISH
Fig. 6
Fig. 7
B
Fig. 9