Download  Print this page

Nokia MetroSite Requirements For Installation And Operation

Edge base station.
Hide thumbs

Advertisement

DN9913471
Issue 3-0 en
Nokia MetroSite EDGE Base Station
Requirements for Installation and
Operation
© Nokia Corporation
Nokia Proprietary and Confidential
Draft
1 (44)

Advertisement

   Also See for Nokia MetroSite

   Summary of Contents for Nokia MetroSite

  • Page 1 Nokia MetroSite EDGE Base Station Requirements for Installation and Operation Draft DN9913471 © Nokia Corporation 1 (44) Issue 3-0 en Nokia Proprietary and Confidential...
  • Page 2 This documentation is intended for the use of Nokia's customers only for the purposes of the agreement under which the documentation is submitted, and no part of it may be reproduced or transmitted in any form or means without the prior written permission of Nokia.
  • Page 3 Hereby, Nokia Corporation, declares that this product is in compliance with the essential requirements and other relevant provisions of Directive: 1999/5/EC. 0523 The product is marked with the CE marking and Notified Body number according to the Directive 1999/5/EC FCC §15.21 - Information to user - This product is used as an intentional radiated equipment and any changes or modifications on the equipment without any approval...
  • Page 4 Requirements for Installation and Operation Draft 4 (44) © Nokia Corporation DN9913471 Nokia Proprietary and Confidential Issue 3-0 en...
  • Page 5: Table Of Contents

    Safety 19 Installation requirements 21 Checking the site 21 Space requirements 21 3.2.1 Nokia MetroSite Base Station dimensions and weight 22 3.2.2 Clearances around BTS 22 Mounting locations and positions 24 Requirements for wall and pole installation 26 Grounding 27 Mains power 28 3.6.1...
  • Page 6: List Of Tables

    Permitted operating voltage fluctuation Table 6. Connectors, cables and recommended fuses Table 7. MetroSite BTS connectors Table 8. Transmission connectors of the Nokia MetroSite EDGE Base Station Draft 6 (44) © Nokia Corporation DN9913471 Nokia Proprietary and Confidential Issue 3-0 en...
  • Page 7: List Of Figures

    List of figures Figure 1. Dimensions of the Nokia MetroSite EDGE Base Station cabinet 22 Figure 2. Clearances around Nokia MetroSite EDGE Base Station 23 Figure 3. Mounting of the Nokia MetroSite EDGE Base Station 25 Figure 4. Power consumption of the Nokia MetroSite EDGE Base Station 29 Figure 5.
  • Page 8 Requirements for Installation and Operation Draft 8 (44) © Nokia Corporation DN9913471 Nokia Proprietary and Confidential Issue 3-0 en...
  • Page 9 ETS 300 019 1-2:1992 class 2.2 upgraded to class 2.3 following vibration test results • Note added about horizontal mounting not being suitable for BTSs with the WCUA cover Draft DN9913471 © Nokia Corporation 9 (44) Issue 3-0 en Nokia Proprietary and Confidential...
  • Page 10 Requirements for Installation and Operation Draft 10 (44) © Nokia Corporation DN9913471 Nokia Proprietary and Confidential Issue 3-0 en...
  • Page 11: About This Document

    About this document About this document This document introduces the requirements set by the Nokia MetroSite EDGE Base Station for successful installation and operation. Use this document as the source for the following information needed in the planning of an installation: •...
  • Page 12 Requirements for Installation and Operation Draft 12 (44) © Nokia Corporation DN9913471 Nokia Proprietary and Confidential Issue 3-0 en...
  • Page 13: Environment

    This section defines the environmental conditions to which the Nokia MetroSite EDGE Base Station can be exposed to during storage. Caution The Nokia MetroSite EDGE Base Station must be stored in its original package before the installation. 2.1.1 International standard for storage According to the standard ETS 300 019-1-1:1992, the storage class for the Nokia MetroSite EDGE Base Station is class 1.2: weather-protected, partly temperature-...
  • Page 14: Mechanical Conditions For Storage

    Conditions of water from sources other than dripping water rain Conditions of icing and frosting 2.1.3 Mechanical conditions for storage The Nokia MetroSite EDGE Base Station complies with the standard ETS 300 019-1-1:1992 class 1.2. Draft 14 (44) © Nokia Corporation DN9913471...
  • Page 15: Transportation

    The Nokia MetroSite EDGE Base Station must be transported in its original package to the installation site. Note The Nokia MetroSite EDGE Base Station is delivered to the customer with the ordered plug-in units pre-installed. 2.2.1 International standard for transportation According to the standard ETS 300 019-1-2:1992, the class for the Nokia MetroSite EDGE Base Station equipment is class 2.3.
  • Page 16: Table 2. Climatic Conditions For Transportation

    Precipitation, rain 6 mm/min 0.24 in/min Radiation, solar 1120 W/m Radiation, heat 600 W/m Water from sources other than rain 1 m/s 3.28 ft/s Wetness none Draft 16 (44) © Nokia Corporation DN9913471 Nokia Proprietary and Confidential Issue 3-0 en...
  • Page 17: Mechanical Conditions For Transportation

    However, for the temperature and humidity values, the table presents extended operational climatic conditions, which differ from class 4.1. The weather shielding of the Nokia MetroSite EDGE Base Station is valid when the BTS is mounted in the recommended positions.
  • Page 18: Table 3. Climatic Conditions For Operation (class 4.1, Extended)

    Requirements for Installation and Operation Table 3. Climatic conditions for operation (class 4.1, extended) Extended value for Nokia Environmental Class 4.1 value MetroSite EDGE Base parameter Station Low air temperature -33°C -40°C -27°F -40°F High air temperature +40°C +50°C +104°F +122°F...
  • Page 19: Mechanical Conditions For Operation

    2.3.6 EMC shielding The chassis and the units of the Nokia MetroSite EDGE Base Station together provide the electromagnetic compatibility (EMC) shielding. The EMC shielding complies with the standards listed in Nokia MetroSite EDGE Base Station: Product Description.
  • Page 20 Requirements for Installation and Operation Draft 20 (44) © Nokia Corporation DN9913471 Nokia Proprietary and Confidential Issue 3-0 en...
  • Page 21: Installation Requirements

    Refer to Nokia MetroSite EDGE Base Station: Installation for details. Space requirements The Nokia MetroSite EDGE Base Station can be mounted on a wall or pole. This section presents the general issues that must be considered when choosing the installation space.
  • Page 22: Nokia Metrosite Base Station Dimensions And Weight

    The Nokia MetroSite EDGE Base Station with four TRXs installed weighs approximately 40 kg (88.4 lb). The mounting rack weighs approximately 2 kg (4.4 lb). The dimensions and weights of the plug-in units can be found in Nokia MetroSite EDGE Base Station: Product Description.
  • Page 23: Figure 2. Clearances Around Nokia Metrosite Edge Base Station

    300 (11.9) 310 (12.2) Figure 2. Clearances around Nokia MetroSite EDGE Base Station The packing cardboard in the BTS transportation package includes a marked-out template for defining the clearances around the BTS and for marking the drilling holes needed for wall mounting. Use the template for defining how much space...
  • Page 24: Mounting Locations And Positions

    Installation for more information on using the cardboard template. Mounting locations and positions The Nokia MetroSite EDGE Base Station can be mounted on a wall or on a pole. Both indoor and outdoor applications are possible. The Nokia MetroSite EDGE Base Station can also be mounted horizontally in the position shown in Figure 3, item B.
  • Page 25: Figure 3. Mounting Of The Nokia Metrosite Edge Base Station

    A) Vertical mounting B) Horizontal mounting Figure 3. Mounting of the Nokia MetroSite EDGE Base Station Note If there is a risk that lumps of snow or pieces of ice can fall onto the BTS (from the antenna or microwave radio pole, for example), an effective roof must be mounted to shield the BTS.
  • Page 26: Requirements For Wall And Pole Installation

    BTS. Anchor screws Anchor screws are used for attaching the Nokia MetroSite EDGE Base Station to the wall. These screws are not included in the delivery. The anchor screws must be M6 size, stainless steel, and with the minimum...
  • Page 27: Grounding

    Installation requirements Grounding To protect the Nokia MetroSite EDGE Base Station from damaging over voltages through antenna equipment, communication cables, or power supply lines, grounding cabling must be planned and installed before installation of the base station. To avoid interference, it is recommended that large grounding systems be designed case-specifically.
  • Page 28: Mains Power

    Mains power WARNING The power switch on the power supply unit (PSU) of the Nokia MetroSite EDGE Base Station does not disconnect it from the power network (AC or DC), but leaves it in a stand-by mode. The switch has two positions: ON and stand-by.
  • Page 29: Figure 4. Power Consumption Of The Nokia Metrosite Edge Base Station

    BTS is increasing. When the ambient temperature rises, the heating power reduces. Consequently, the power consumption of the Nokia MetroSite EDGE Base Station at a given temperature varies according to the direction of temperature change. Figure 4 presents the power consumption values at different ambient temperatures for three BTS configurations.
  • Page 30: Acoustic Sound Power

    Requirements for Installation and Operation 3.6.2 Acoustic sound power The fan unit of the Nokia MetroSite EDGE Base Station generates acoustic noise. The level of acoustic sound power is dependent on the following factors: • ambient temperature • rate of the temperature change •...
  • Page 31: Connectors, Cables, And Fuses For Cable Protection

    Prefabricated mains power cables can be ordered from Nokia. Note If you use the prefabricated mains power cable supplied by Nokia, make sure that the power distribution box (mains power supply) is located no further than 10 metres from the BTS’s power supply unit.
  • Page 32: Painting The Bts Cover

    In general, the fuses for cable protection must be rated according to the national electrical safety regulations. For information on the pin configurations for the different BTS power supply connector types, refer to Nokia MetroSite EDGE Base Station: Product Description. Painting the BTS cover...
  • Page 33: Figure 6. Removing The Top Of The Bts Cover

    -40°C to +50°C (-40°F to 122°F). For environmental conditions, refer to ETS 300 019-1-4:1992 class 4.1. Painting the BTS cover Remove the BTS cover as instructed in Nokia MetroSite EDGE Base Station: Maintenance. Before painting, detach the cable cover and remove the cable cover support.
  • Page 34: Figure 7. Areas Used For Holding The Cable Cover Parts During Painting

    See Figure 7 for areas on which to place the clamp. Figure 7. Areas used for holding the cable cover parts during painting Draft 34 (44) © Nokia Corporation DN9913471 Nokia Proprietary and Confidential Issue 3-0 en...
  • Page 35 The temperature of the drying oven must not exceed 90°C (194°F). When the paint is dry, attach the cover top to the cover. Tighten the screws to 1.6 Nm (1.18 lb ft). Draft DN9913471 © Nokia Corporation 35 (44) Issue 3-0 en Nokia Proprietary and Confidential...
  • Page 36 Requirements for Installation and Operation Draft 36 (44) © Nokia Corporation DN9913471 Nokia Proprietary and Confidential Issue 3-0 en...
  • Page 37: Cabinet Interfaces And Cables

    Nokia MetroSite EDGE Base Station: Product Description. Note Antenna line cables, the LMP cable, Abis cables and Flexbus cables can be ordered from Nokia. The MetroSite BTS interface connectors and cables are described in Tables 7 and Table 7. MetroSite BTS connectors Interface...
  • Page 38: Cable Entry Block

    E1 20 dB, for T1 26 dB Cable entry block The size of the cable entry holes must be considered when planning the cabling of the Nokia MetroSite EDGE Base Station. The holes can accommodate various cable diameters, as shown in Figure 8. Draft 38 (44) ©...
  • Page 39: Figure 8. Cable Entry Block: Cable Diameters

    - Grounding cable, 1 pc - Transmission cables, max 8 pcs - External alarms and controls NOTE: DIMENSIONS mm (inch) Figure 8. Cable entry block: cable diameters Draft DN9913471 © Nokia Corporation 39 (44) Issue 3-0 en Nokia Proprietary and Confidential...
  • Page 40 Requirements for Installation and Operation Draft 40 (44) © Nokia Corporation DN9913471 Nokia Proprietary and Confidential Issue 3-0 en...
  • Page 41: Installation Equipment

    Installation equipment Installation equipment This section specifies the equipment that is recommended for the installation of the Nokia MetroSite EDGE Base Station. This equipment is not included in the BTS delivery. Torque driver (0-6 Nm/0-5 ft-lb) with: Torque socket spanner/wrench - T10 Torx bit with min.
  • Page 42 BTS • crimping tool for fitting a crimp terminal to the grounding cable Note A set of tools needed for assembling the cable connectors is available from Nokia. • cable stripper for preparing the grounding cable •...
  • Page 43: Index

    The cable entry block is made of a flexible grounding points material.cable entry block tools transportation climatic conditions ingress protection international standard for installation mechanical conditions requirements for Draft DN9913471 ©Nokia Corporation 43 (44) Issue 3-0 en Nokia Proprietary and Confidential...
  • Page 44 Requirements for Installation and Operation ventilation weight mounting rack Draft 44 (44) © Nokia Corporation DN9913471 Nokia Proprietary and Confidential Issue 3-0 en...