Interfaces - Mitsubishi Electric MELSERVO-J2S-S061 Specifications And Instruction Manual

General purpose ac servo, built-in positioning function
Table of Contents

Advertisement

4. Interfaces

This section gives the details of the I/O signal interfaces.
(1) Digital input interface DI-1
Give a signal with a relay or open collector transistor.
Source input is also possible. Refer to (5) in this section.
For use of internal power supply
(Note)
For a transistor
Approx. 5mA
Switch
TR
V
1.0V
CES
I
100 A
CEO
Note: This also applies to the use of the external power supply.
(2) Digital output interface DO-1
A lamp, relay or photocoupler can be driven. Provide a diode (D) for an inductive load, or an inrush
current suppressing resister (R) for a lamp load. (Permissible current: 40mA or less, inrush current:
100mA or less)
1) Inductive load
For use of internal power supply
Servo amplifier
24VDC
VDD
COM
ALM, etc.
SG
Servo amplifier
24VDC
VDD
R: Approx. 4.7k
COM
SON, etc.
SG
Load
If the diode is not
connected as shown,
the servo amplifier
will be damaged.
For use of external power supply
Do not connect
VDD-COM.
24VDC
200mA or more
Switch
For use of external power supply
Servo amplifier
VDD
COM
ALM, etc.
SG
16
Servo amplifier
VDD
R: Approx. 4.7k
COM
SON, etc.
SG
Do not connect
VDD-COM.
Load
27VDC or
less
If the diode is not
connected as shown,
the servo amplifier
will be damaged.
BCN-B11127-479*

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j2s-**a-s061 series

Table of Contents