CHAPTER 1 MAINTENANCE AND SERVICING
A.
Main Unit
1.
Periodic replacement parts
There are no parts in the unit that need to be periodically replaced.
2.
Estimated lifespan of consumable parts
It may be necessary to replace parts due to wear or damage more than once during
the warranty period. The expected life (number of pages) of parts that do not need to be
replaced until they fail is indicated below.
no.
Part Name
1
Fixing assembly
2
Transfer corona
assembly roller
3
Paper feed roller
4
Separation roller,
transport roller
5
Multi-feeder paper
feed roller
6
Multi-feeder separa-
tion pad
7
Exhaust fan
*1
A total of 4, including the main unit and a single level cassette feeder
A total of 8, including the main unit and a three-level cassette feeder
*2
A total of 4, including the main unit and a single level cassette feeder (2 separa-
tion rollers and 2 transport rollers)
A total of 8, including the main unit and a three-level cassette feeder (4 separa-
tion rollers and 4 transport rollers)
:
Caution
The information in the table above is only an estimate, and may be revised in the light
of empirical data.
Part No.
Number of
parts
FG6-1259-000
1
RG5-3527-000
1
RB2-1821-000
2*
RF5-2490-000
1 each *
RB2-1820-000
1
RF5-2400-000
1
RH7-1354-000
1
Table 1-1
CHAPTER 1 MAINTENANCE AND SERVICING
As of January, 1999
Estimated Number
of Pages Copied
150,000
150,000
200,000
1
2
200,000
200,000
200,000
25,000 hours
1
Remarks
25,000 hours
is 3 years of
24-hour con-
tinuous power
supply
1-1