SVMi-8 Setup with DCS Phone Systems

This section provides the additional steps required to set up the SVMi-8 card for operation in all DCS telephone
systems. Included here is information regarding the software setup for the phone systems.
After inserting the SVMi-8 card and turning the power on there are some key system options that should be set, in
order for the SVMi-8 to function correctly. These steps are performed in the phone system. It is necessary to per-
form these at this time so that the SVMi-8 will initialize properly and synchronize its mailbox database with that of
the key system.

Power Up Procedure

Follow the steps below to ensure that the SVMi-8 is properly set up.

POWER UP

1. Complete insertion of the SVMi-8 and all other required interface cards and turn the system power switch ON.
2.
There are two LEDs on the front of SVMi-8: a RUN LED and an HDD LED.
The RUN LED-This will show steady green when the system has completed booting up.
The HDD LED-This will show hard disk drive (HDD) access and will flicker when the HDD is being accessed.

SYSTEM PROGRAMMING

Perform the following programming. It is necessary to perform these at this time so that the SVMi-8 will read these
MMCs and initialize accordingly.
1. MMC 601: All SVMi-8 ports installed must be assigned to group 529 (DCS) or 519 (Compact II) or 549 (iDCS500).
2. MMC 601: Select either SEQUENTIAL or DISTRIBUTED ring mode.
3. If you are using SVMi-8 for Auto Attendant use MMC 406 to set the desired trunk(s) to ring group 519 / 529 / 549.
4.
If you are using SVMi-8 for Voice Mail make sure that all desired stations are forwarded to group 519 / 529 / 549.
5.
MMC 751: Select "NO" for each station that you DO NOT want to create a mailbox for.
INITIALIZING THE SVMi-8
Press the red RST button to read the MMC data and initialize SVMi-8 accordingly.
NOTE: After the SVMi-8 restarts you should change the value of MMC 750 so that it indicates "download = No." This
will prevent the system from overwriting any future changes you make to the SVMi-8 database.