Coincidence Detection Interrupt Function - Mitsubishi Electric RD62P2E Application User's Manual

High-speed counter module
Table of Contents

Advertisement

Coincidence detection interrupt function

This function outputs an interrupt request to the CPU module and starts an interrupt program when the present counter value
matches with the preset coincidence output point setting value.
For details on the interrupt program, refer to the following.
 MELSEC iQ-R CPU Module User's Manual (Application)
Interrupt factor
The high-speed counter module has interrupt factors of 4 points for each coincidence output point.
Interrupt factor
Turning on CH1 Counter value coincident (point No.1) (X2)
Turning on CH1 Counter value coincident (point No.2) (X6)
Turning on CH2 Counter value coincident (point No.1) (X9)
Turning on CH2 Counter value coincident (point No.2) (XD)
Interrupt program execution timing
CH1 Counter value coincident (point No.1) (X2)
CH1 Counter value coincident (point No.2) (X6)
I/O signals
CH1 Coincidence signal No.1 reset command (Y0)
CH1 Coincidence signal No.2 reset command (Y7)
Interrupt request
Internal
processing of
CPU module
Interrupt request clear
Program in CPU module
Setting interrupt pointers
Set interrupt pointers in the parameter settings. For details on the setting method, refer to the following.
Page 42 Interrupt Setting
• A coincidence detection interrupt occurs on the rising edge of the counter value coincidence signal (When
the signal is turned off and on). Therefore, the next interrupt will not be requested unless the coincidence
signal is reset and the counter value coincidence signal is turned off.
Interrupt program
1 FUNCTIONS
1.3 Coincidence Output Function
1
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd62d2Melsec iq-r seriesRd62p2

Table of Contents