PERSONALITY - Status Settings - Address Via DMX
When ON, define the desired DMX address via an external controller.
1.   Connect the fixture to the external controller and power ON.
2.   Set the DMX value of Channel 1 on the controller to (7).
3.   Set the DMX value of Channel 2 on the controller to (7) or (8).
When set to (7), the DMX address can be set between (1) and (255).
When set to (8), the DMX address can be set between (256) and (511).
4.   Using Channel 3 on the controller set the desired DMX address of the fixture.
Example 1: If the desired DMX address is 57, set Channel 1 to a value of (7), set
Channel 2 to a value of (7), and then set Channel 3 to a value of (57).
Example 2: If the desired DMX address is 420, set Channel 1 to a value of (7), set
Channel 2 to a value of (8), and then set Channel 3 to a value of (164). (256+164=420)
5.   After setting Channel 3 to the desired DMX address value, wait for approximately 20
seconds for the fixture to complete the address reset function.
PERSONALITY – Service Setting - Password (050)
NOTE: The Service Password MUST be entered in order to access the following menus:
RDM PID, Ethernet IP, Ethernet IP Mask, and Clear Err. Info.
PERSONALITY – Service Setting - RDM PID
Select various submenus via RDM. RDM stands for "Remote Device Management", which
provides the ability to control the device remotely while connected to a DMX-bus. ANSI
E1.20-2006 by ESTA specifies the RDM standard as an extension of the DMX512 protocol.
Manual settings like adjusting the DMX starting address are no longer needed. This is
especially useful when the device is installed in a remote area.
RDM ready and conventional DMX devices can be operated in one DMX line. The RDM
protocol sends its own packages in the DMX512 data feed and does not influence
conventional devices. If DMX splitters are used and RDM control is to be used, these
splitters must support RDM. The number and type of RDM parameters depend on the RDM
controller being used.
PERSONALITY - Display Setting – Key Lock
When ON, Control Panel buttons lock automatically after exiting main menu for 15 seconds.
To unlock, keep MODE/ESC button pressed for 3 seconds.