A. Do not place the contact element against the work-
piece with excessive force.
B. Pull the trigger fully and hold it on for 1-2 seconds
after stapling.
Direction of exhaust air
► 1. Exhaust cover
The direction of exhaust air can be changed 360
degrees of angle by turning the exhaust cover with a
hand.

Removing jammed staples

WARNING:
Always disconnect the hose before removing
staplers.
Remove the staples from the magazine.
Lift up the latch on the top of driver guide by hand.
1
► 1. Driver guide 2. Latch
If the latch cannot be lift up by hand, insert a slotted bit
screwdriver in the gap between the latch and the door
and force it up.
1
► 1. Slotted bit screwdriver 2. Latch 3. Door
Open the door and take out staples.
► 1. Door
Place the latch spring on two hooks of the driver guide
and return it to its original position by pressing it.
2
► 1. Driver guide 2. Latch
CAUTION:
If the tip of staple driver has worn, staple jam-
ming and shallow driving will tend to occur.
When this occurs, have it repaired by Makita
Authorized or Factory Service Centers.