Download Print this page

Mitsubishi Electric FR-F746-EC Instruction Manual Supplement page 4

Advertisement

4. Rating
SLD is initially set.
Type FR-F746-
-EC
Applied motor capacity
(kW) *1
Rated
LD
capacity
SLD
(kVA) *2
LD
Rated
current(A)
*3
SLD
Overload
LD
current
SLD
rating *4
Voltage *5
Rated input AC
voltage/frequency
Permissible AC
voltage fluctuation
Permissible
frequency
fluctuation
Power
LD
supply
system
capacity
SLD
(kVA) *6
Protective structure
Cooling system
Approx. mass
LD
Ambient
temperature
SLD
*1
The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole
standard motor.
*2
The rated output capacity indicated assumes that the output voltage is 440V.
*3
When operating the inverter with the carrier frequency set to 3kHz or more, the carrier frequency automatically
decreases if the inverter output current exceeds the value in parenthesis of the rated current. This may cause the
motor noise to increase.
*4
The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated
output current. For repeated duty, allow time for the inverter and motor to return to or below the temperatures
under 100% load.
*5
The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be
changed within the setting range. However, the pulse voltage value of the inverter output side voltage remains
unchanged at about
*6
The power supply capacity varies with the value of the power supply side inverter impedance (including those of
the input reactor and cables).
00023 00038 00052 00083 00126 00170 00250 00310 00380 00470 00620 00770 00930 01160
0.75
1.5
2.2
3.7
1.6
2.7
3.7
5.8
2.1
3.5
4.8
7.6
(1.8)
(3.0)
(4.1)
(6.5)
2.3
3.8
5.2
8.3
(2.0)
(3.2)
(4.4)
(7.1)
2.5
4.5
5.5
Self cooling
12.5
-10°C to 40°C (non-freezing)
-10°C to 30°C (non-freezing)
that of the power supply.
2
5.5
7.5
11
8.8
12.2 17.5 22.1 26.7 32.8 43.4 53.3 64.8 80.8
11.5
16
23
(9.8)
(13.6)
(20)
12.6
17
25
(10.7)
(14.5)
(21)
120%60s, 150%3s, Ambient temperature 40°C
110%60s, 120%3s, Ambient temperature 30°C
Three-phase 380V-480V
Three-phase 380V-480V 50/60Hz
323 to 528V 50Hz/60Hz
±5%
9
12
17
20
IP54
18.5
4/8
15
18.5
22
30
29
35
43
57
(25)
(30)
(37)
(48)
31
38
47
62
(26)
(32)
(40)
(53)
28
34
41
52
Forced air cooling
21.5
30
BCN-C22005-352
37
45
55
70
85
106
(60)
(72)
(90)
77
93
116
(65)
(79)
(99)
66
80
100
27
42
42

Advertisement

loading

This manual is also suitable for:

Fr-f700 series