INSTALLATION
(5) For wiring of 22K or less, remove a hook of the front cover and use a space become available.
For wiring of 30K or more, use the space on the left side of the control circuit terminal block.
22K or less
REMARKS
When the hook of the inverter front cover is cut off for wiring, the protective structure (JEM1030) changes to open type
(IP00).
Do not use empty terminals as junction terminals because they are used in the option unit. If
they are used as the junction terminals, the option unit may be damaged.
When performing wiring using the space between the inverter front cover and control circuit
terminal block, take care not to subject the cable to stress.
After wiring, wire offcuts must not be left in the inverter. They may cause a fault, failure or
malfunction.
12
Cut off
with a
nipper,
etc.
Cut off a hook on the inverter
front cover side surface.
(Cut off so that no portion is left.)
CAUTION
Control circuit
terminal block
30K or more