Step 5.
Set the controller module aside in a safe place, and repeat these steps if you have another
controller module in the chassis.

Moving drives to the new chassis

You need to move the drives from each bay opening in the old chassis to the same bay opening in the new
chassis.
Step 1.
Gently remove the bezel from the front of the system.
Step 2.
Remove the drives:
a.
Press the release button at the top of the carrier face below the LEDs.
b.
Pull the cam handle to its fully open position to unseat the drive from the midplane, and then
gently slide the drive out of the chassis.
The drive should disengage from the chassis, allowing it to slide free of the chassis.
Attention: When removing a drive, always use two hands to support its weight.
Attention: Drives are fragile. Handle them as little as possible to prevent damage to them.
Step 3.
Align the drive from the old chassis with the same bay opening in the new chassis.
Step 4.
Gently push the drive into the chassis as far as it will go. The cam handle engages and begins to
rotate upward.
Step 5.
Firmly push the drive the rest of the way into the chassis, and then lock the cam handle by pushing
it up and against the drive holder. Be sure to close the cam handle slowly so that it aligns correctly
with the front of the drive carrier. It click when it is secure.
Step 6.
Repeat the process for the remaining drives in the system.

Replacing a chassis from within the equipment rack or system cabinet

You must remove the existing chassis from the equipment rack or system cabinet before you can install the
replacement chassis.
Step 1.
Remove the screws from the chassis mount points.
Step 2.
With the help of two or three people, slide the old chassis off the rack rails in a system cabinet or L
brackets in an equipment rack and set it aside.
Step 3.
If you are not already grounded, properly ground yourself.
Step 4.
Using two or three people, install the replacement chassis into the equipment rack or system
cabinet by guiding the chassis onto the rack rails in a system cabinet or L brackets in an equipment
rack.
.