Smeg KR37X Instruction Manual
Smeg KR37X Instruction Manual

Smeg KR37X Instruction Manual

Smeg ventilation hood user manual

Advertisement

Quick Links

Libretto di Istruzioni
Instructions Manual
Manuel d'Instructions
Bedienungsanleitung
Gebruiksaanwijzing
Manual de instrucciones
Manual de Instruções
Bruksanvisning
KR37X

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KR37X and is the answer not in the manual?

Questions and answers

Summary of Contents for Smeg KR37X

  • Page 1 Libretto di Istruzioni Instructions Manual Manuel d’Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instruções Bruksanvisning KR37X...
  • Page 2: Table Of Contents

    INDICE CONSIGLI E SUGGERIMENTI ...4 CARATTERISTICHE ...5 INSTALLAZIONE...6 USO ...10 MANUTENZIONE ...11 INDEX RECOMMENDATIONS AND SUGGESTIONS ...13 CHARACTERISTICS...14 INSTALLATION ...15 USE...19 MAINTENANCE...20 SOMMAIRE CONSEILS ET SUGGESTIONS ...22 CARACTERISTIQUES ...23 INSTALLATION ...24 UTILISATION...28 ENTRETIEN...29 INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE...31 CHARAKTERISTIKEN...32 MONTAGE...33 BEDIENUNG...37 WARTUNG...38 INHOUDSOPGAVE ADVIEZEN EN SUGGESTIES ...40...
  • Page 3 ÍNDICE CONSELHOS E SUGESTÕES ...58 CARACTERÍSTICAS ...59 INSTALAÇÃO ...60 UTILIZAÇÃO...64 MANUTENÇÃO ...65 ...67 ...68 ...69 ...73 ...74 INNEHÅLL REKOMMENDATIONER OCH TIPS...76 EGENSKAPER ...77 INSTALLATION ...78 ANVÄNDING...82 UNDERHÅLL ...83...
  • Page 4: Recommendations And Suggestions

    RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this appliance. Accord- ingly, you may find descriptions of individual features that do not apply to your specific appliance. INSTALLATION • The manufacturer will not be held liable for any damages resulting from incor- rect or improper installation.
  • Page 5: Characteristics

    CHARACTERISTICS Components Ref. Q.ty Product components Hood equipped with: Controls, Lights, Filters Hood support equipped with the Exhaust Group tube in PVC Directioned grid Air outlet reduction ø 120mm Reduction flange ø 150-120 mm Ref. Q.ty Installation components Small blocks ø 10 Screws 5 x 70 Screws M4 x 15 Screws 2,9 x 9,5...
  • Page 6 INSTALLATION Wall drilling and bracket fixing When installing the hood in recycling version it has to be taken into consideration that space re- maining between the hood and the upper limit (ceiling or self) is at least 8-10 cm. On the wall, draw: •...
  • Page 7 Hood support mounting • Lean the hood support 3 against the wall making sure that holes in the hood support correspond to those in the wall. • Block the hood support to the wall using 4 12a (5 x 70) screws supplied with the hood.
  • Page 8: Recirculation Version Air Outlet

    RECIRCULATION VERSION AIR OUTLET • Insert pvc pipe 7 provided onto the Hood Canopy Outlet. Hood body mounting Ducting version • In case the air outlet connection on the upper part of the hood has been chosen it will be necessary to remove the pre-cut piece.
  • Page 9: Electrical Connection

    ELECTRICAL CONNECTION • Connect the hood to the mains through a twopole switch having a contact gap of at least 3 mm. • Open the lighting unit by pulling on the notch. • Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time.
  • Page 10 Button Function Press briefly to turn the lighting system on and off. Press and hold for approx. 2 seconds to turn the lighting system on and off at reduced intensity. Turn the suction motor on and off at speed one. If the filter saturation alarm is on, this resets it.
  • Page 11: Maintenance

    MAINTENANCE Metal grease filters These can also be washed in the dishwasher, and need to be cleaned when all the command LEDs light up in a continuous manner or at least once every 2 months use, or more frequently if use is particularly intensive.
  • Page 12: Installation

    Activated Charcoal Filter (Recirculation Version) • This cannot be washed or regenerated, and must be changed when all the command LEDs start to flash, or at least once every 4 months. Activating the alarm signal • In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installation or at a later date.