n
Hex number for the slot number, MCT number or statistic number being
changed.
data
Hex bytes.
v MCT: Two bytes for each location in the MCT table. The table is 256
locations of two bytes each. MCTs that are not defined are set as 0xffff.
v Stat: Two bytes for each location in the statistics table. The table is 256
locations of two bytes each. Statistics that are not defined are set as
0xffff.
databytes
Two hex bytes associated with the traps being set:
Bit 15 Cash Drawer Open / Closed
Bit 14 Magnetic Noise present (MICR read)
Bit 13 Paper Out
Bit 12 Paper Low
Bit 11 Home Error
Bit 10 Paper Jam
Bit 9
Cutter Jam
Bit 8
CR Cover Open / Closed
Bit 7
DI Cover Open / Closed
Bit 6
Hard Error at the printer (printer offline). MLC error / IFC error /
Firmware can not initialized motion sensor and/or thermal print
head.
Bits 2 - 5
Reserved - should remain high
Bit 0, 1
Version option for returning Trap messages – SNMP manager 1:
11
10
01
Details:
snmptrap1:
Bit 15 Cash Drawer Open / Closed
Bit 14 Magnetic Noise present (MICR read)
Bit 13 Paper Out
Bit 12 Paper Low
Bit 11 Home Error
Bit 10 Paper Jam
Bit 9
Cutter Jam
Bit 8
CR Cover Open / Closed
Bit 7
DI Cover Open / Closed
Version 1
Version 2
Version 3 (Currently not supported)