Hardware Configuration:
1. Take the printer connector(maile) of a DDC multi-cable
plugged into the printer socket (female) of a desktop PC
or laptop as '1 PRINTER'.
2. Take the USB connector of the DDC multi-cable plugged
into the USB socket of a desktop PC or laptop.
3. Take a standard D-sub cable (male-male) to connect the
D-Sub video port (female) of monitor and D-Sub
connector (female) of the DDC multi cable.
4. Check all cables are well connected.
VGA CONNECTION
S1 Open EDID Write protection function
Turn off the power,then press force on " POWER " and " E
" button at the same time then press on " MENU "button to
enter factory mode.
Select "EDID WP" to let it be off.
Note: Please pay attention ,Don't change any parameter
which is measured by precise machine before shipping
out.
7. Writing EDID Process
PARALLEL CONNECTION
USB CONNECTION
Writing EDID for VGA
(1A)
S1 Chose the folder:" Acer-V233H-edid-VGA "
Double click " AcerEDID-Ana_only.EXE "
S2 Select Model: Key in password"cedid" then select
model which one you want to write EDID code that it
depends on panel type.
cedid
ACER V233H
Go to cover page
SS MEANS SAMSUNG PANEL