Par.
Description
c48
Activation of output 4
c49
Diff erential/logic of output 4
d46
Activation restriction for output 4
d47
Deactivation restriction for output 4
d48
Minimum value of modulating output 4(*)
d49
Maximum value of modulating output 4(*)
c50
Disable keypad and remote control
c51
Code for enabling the remote control
0=Programming from remote control without code
c52
Display
0=Probe 1
1=Probe 2
2=Digital input 1
3=Digital input 2
c53
Buzzer
0=Enabled
1=Disabled
c56
Delay at start-up
c57
Soft start(*)
c62
ti_PID
c63
td_PID
c64
Auto-Tuning
0=Disabled
1=Enabled
c66
Enabling direct threshold(*)
Validity: c0 =1,2
c67
Enabling reverse threshold(*)
Validity: c0 =1,2
c68
Enable Cut off operation
0=Cut off enabled
1=Cut off disabled
P70
Enable operating cycle
0=Disabled
1=Keypad
2=Digital input
3=RTC
P71
Operating cycle: duration of step 1
P72
Operating cycle: temperature set point step 1
P73
Operating cycle: duration of step 2
P74
Operating cycle: temperature set point step 2
P75
Operating cycle: duration of step 3
P76
Operating cycle: temperature set point step 3
P77
Operating cycle: duration of step 4
P78
Operating cycle: temperature set point step 4
P79
Operating cycle: duration of step 5
P80
Operating cycle: temperature set point step 5
AL0
Date – time of alarm 0 (press Set)
(y=year ,M=month,d=day,h=hours,m=minutes)
y
AL0_y = year of alarm 0
M
AL0_M = month of alarm 0
d
AL0_d = day of alarm 0
h
AL0_h = hours of alarm 0
m
AL0_m = minutes of alarm 0
E
AL0_t = type of alarm 0
AL1
Date – time of alarm 1 (press Set)
(y=year ,M=month,d=day,h=hours,m=minutes)
y
AL1_y = year of alarm 1
M
AL1_M = month of alarm 1
d
AL1_d = day of alarm 1
h
AL1_h = hours of alarm 1
m
AL1_m = minutes of alarm 1
E
AL1_t = type of alarm 1
AL2
Date – time of alarm 2 (press Set)
(y=year ,M=month,d=day,h=hours,m=minutes)
y
AL2_y = year of alarm 2
M
AL2_M = month of alarm 2
d
AL2_d = day of alarm 2
h
AL2_h = hours of alarm 2
m
AL2_m = minutes of alarm 2
E
AL2_2 = type of alarm 2
AL3
Date – time of alarm 3 (press Set)
(y=year ,M=month,d=day,h=hours,m=minutes)
y
AL3_y = year of alarm 3
M
AL3_M = month of alarm 3
d
AL3_d = day of alarm 3
h
AL3_h = hours of alarm 3
m
AL3_m = minutes of alarm 3
E
AL3_t = type of alarm 3
Note Def Min
Max UoM
-100 -100
100
%
25
-100
100
%
3
0
3
-
0
0
4
-
0
0
100
%
100 0
100
%
1
0
2
-
1
0
255
-
0
0
3
-
0
0
1
-
0
0
255
s
0
0
99
min
600 0
999
s
0
0
999
s
0
0
1
-
-50
-50
150
°C/°F
150 -50
150
°C/°F
0
0
1
-
0
0
3
-
0
0
200
min
0
-50
150
°C/°F
0
0
200
min
0
-50
150
°C/°F
0
0
200
min
0
-50
150
°C/°F
0
0
200
min
0
-50
150
°C/°F
0
0
200
min
0
-50
150
°C/°F
-
-
-
-
0
0
99
year
0
1
12
month
0
1
31
day
0
0
23
hours
0
0
59
minutes I
0
0
99
-
-
-
-
-
0
0
99
year
0
1
12
month
0
1
31
day
0
0
23
hours
0
0
59
minutes I
0
0
99
-
-
-
-
-
0
0
99
year
0
1
12
month
0
1
31
day
0
0
23
hours
0
0
59
minutes I
0
0
99
-
-
-
-
-
0
0
99
year
0
1
12
month
0
1
31
day
0
0
23
hours
0
0
59
minutes I
0
0
99
-
39
Typ. CAREL SVP ModBus®
R/W
I
77
150
R/W
I
78
151
R/W
I
79
152
R/W
I
80
153
R/W
I
81
154
R/W
I
82
155
R/W
I
83
156
R/W
I
84
157
R/W
I
85
158
R/W
D
171
33
R/W
I
86
159
R/W
I
87
160
R/W
I
88
161
R/W
I
89
162
R/W
D
172
34
R/W
A
21
22
R/W
A
22
23
R/W
D
173
35
R/W
I
97
170
R/W
I
98
171
R/W
A
23
24
R/W
I
99
172
R/W
A
24
25
R/W
I
100
173
R/W
A
25
26
R/W
I
101
174
R/W
A
26
27
R/W
I
102
175
R/W
A
27
28
R/W
-
-
-
R
I
103
176
R
I
104
177
R
I
105
178
R
I
106
179
R
107
180
R
I
108
181
R
-
-
-
R
I
109
182
R
I
110
183
R
I
111
184
R
I
112
185
R
113
186
R
I
114
187
R
-
-
-
R
I
115
188
R
I
116
189
R
I
117
190
R
I
118
191
R
119
192
R
I
120
193
R
-
-
-
R
I
121
194
R
I
122
195
R
I
123
196
R
I
124
197
R
125
198
R
I
126
199
R
ir33 universale +030220801 - rel. 1.0 - 16.04.2008
ENG
Icon
4
4
4
4
4
4
TUNING
TUNING
TUNING

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents