Download Print this page
Rheem EZiSET 052310 Installation Instructions
Rheem EZiSET 052310 Installation Instructions

Rheem EZiSET 052310 Installation Instructions

Smartphone remote controller

Advertisement

Quick Links

SMARTPHONE REMOTE CONTROLLER (Part No. 052310)
This instruction is for installation of Rheem EziSET
Australia – 876627, 876027, 866627, 866027, 876T26*, 876820*, 876T16* & 876812* Models
New Zealand – 874627, 864627, 874826, 874824, 874820 & 874816 Models
NOTE: Rheem EziSET
PLEASE NOTE:
1. The Rheem EziSET
®
2. Rheem EziSET
3. Do not install this device when a tempering valve or thermostatic mixing valve is already installed in the hot
water line. The cold water valve inside these valves cannot be fully closed after bath fill function has been
completed, leading to continuous cold water dripping from hot water tap if left open after bath fill.
4. Any installed Rheem wired controllers must be disconnected from the water heater.
5. Should the home electrical power supply be 3-phase, the Rheem EziSET
be connected to power outlets supplied by the same phase.
®
6. Rheem EziSET
via their home WiFi network connection. No internet or data services are required.
7. The Rheem EziSET
requires an Ethernet socket in the WiFi router and a power outlet. The PLT plug is plugged into a power outlet
adjacent to the home's WiFi router
8. The Rheem EziSET
compatible to iOS 8.1 (iPhone 5 or later, excluding iPhone 5C) or Android 4.0 version or later.
®
The Rheem EziSET
kit contains:
Item
Component Description
1
Rheem EziSET
2
Top mounting bracket
3
Bottom mounting bracket
4
MAC address label
M4 self tapping screws (required for installation in
5
some models)
6
PLT plug
7
Ethernet cable
INSTALLATION INSTRUCTIONS
heater models (refer to the rating plate for model number
(*manufactured since 2018)
®
must only be installed by a qualified person.
®
module is to be located inside the already-installed Continuous Flow water heater.
MUST NOT be used on a Continuous Flow gas water heater installed as a solar booster.
communicates between the Continuous Flow water heater and the homeowner's smartphones
®
kit includes a PLT plug which has been factory paired. No further set up is required. It
®
smartphone app can be downloaded from App Store or Google Play Store and is
®
module
®
with the following Rheem Electronic Continuous Flow Gas water
Qty
1
1
1
1
3
1
1
1
)
:
®
PLT plug and the water heater MUST

Advertisement

loading

Summary of Contents for Rheem EZiSET 052310

  • Page 1 4. Any installed Rheem wired controllers must be disconnected from the water heater. 5. Should the home electrical power supply be 3-phase, the Rheem EziSET ®...
  • Page 2 ® INSTALLING RHEEM EziSET 1. Close any hot taps and ensure the burners are not operating. 2. Turn off the controller(s), if connected, by pressing the on/off button. Switch off the electrical supply at the power outlet to the water heater and remove the Diagram 1 3 pin plug from the GPO.
  • Page 3 FOR T26, 826, 824, T20, 820, T16, 816 or 812 MODELS ® Note: The Rheem EziSET module is installed in these models via 2 screws onto the rear casing of the water heater as shown in image 8. The Top & Bottom mounting brackets supplied in the kit are not required.
  • Page 4 A new IP address from the router will be stored in the EziSET module. RHEEM AUSTRALIA PTY LTD, A.B.N. 21 098 823 511 – for Service Telephone 131 031 AUSTRALIA RHEEM NEW ZEALAND LTD – for Service Telephone 0800 657 335 NEW ZEALAND...