Service Bulletin 4812 712 40330 - Whirlpool AWO/D 43115 Service Information

Frontloader
Hide thumbs Also See for AWO/D 43115:
Table of Contents

Advertisement

SERVICE

Service Bulletin 4812 712 40330

AUTHOR: Ronny Schuricht
Last Update: 01/21/10
VERSION: 1.0
TITLE: no water inlet, cable connection to valve broken
SUBJECT: In rare cases the wiring between control board and valve gets broken directly at the connector of the valve.
Reason is a too strong fixation of the water inlet hose, done with a pliers. Result is that the valve gets out of its position and
brakes the cable connection. In addition can be created a short circuit on the control board.
REMEDIAL ACTION
Check the control board for short circuit. If necessary exchange the valve. Fixate the valve in the correct position with a
fixation screw. Exchange the harness between control board and valve. Check and If necessary exchange the inlet hoses
between valve and dispenser.
harness (CCU-valve): 4801 111 00724
fixation screw: 4812 023 08092
hose (valve-disp.): 4812 530 29405
© Whirlpool EMEA
Whirlpool EMEA
Customer Services
8592 336 10008, 08/28/08
page 50 of 53
www.scc-service.com