NOTICE
Communication not possible.
Deselect the "Auto" check box only in case of transfer problems.
If you want to change the transfer rate, please contact your network administrator.
Communication between HMI Panel and Access Point is not possible in case of incorrect
settings.
1. Deselect the "Auto" check box.
2. Select the desired data transfer rate in the Maximum Data Rate selection box.
3. Confirm your entries.
4. Confirm the message of the HMI device.
5. Restart the HMI device.
See also
Restarting the HMI device (Page 156)
6.2.2

Parameterizing the WLAN connection

Introduction
You can define the parameters for the WLAN connection and also create new WLAN
connections.
Requirements
You have opened the "WLAN" dialog box, "Wireless" tab, by touching either the "WLAN
Settings" icon or the
If no connection to a WLAN network exists, all available WLAN networks are listed.
If a connection to a WLAN network exists, the following WLAN networks are displayed:
● The WLAN network to which the connection exists
● All parameterized networks
Mobile Panel 277F IWLAN
Operating Instructions, 12/2007, A5E01003940-01
icon.
Configuring the operating system
6.2 WLAN