4.2.5 SSSW-SW05: Setting of Standard Functions (DIS signal)

4.2.5.1 Functional Construction

Bit
Function
0
not used
1
Conversion from mm to inch (text mode)
2
Conversion from mm to inch (text/photo mode)
3
end DIS signal bits 33 and over
4
Recording paper length availability declared in
DIS signal
5
not used
6
not used
7
not used

4.2.5.2 Detailed Discussions of Bit 1

Use it to enable/disable millimeter/inch conversion in sub scanning direction for images
read in text mode.

4.2.5.3 Detailed Discussions of Bit 2

Use it to enable/disable millimeter/inch conversion in sub scanning direction for images
read in text/photo mode while bit 1 is set to '1'.

4.2.5.4 Detailed Discussions of Bit 3

Use it to enable/disable transmission of bit 33 and thereafter (DIS signal).
If 'prohibit' is selected, the Super Fine reception function or Memory Box function
cannot be used for communications from non-Canon machines.
T-4-5
1
-
convert
convert
prohibit
A4/B4 size
-
-
-
Chapter 4
0007-5658
0
-
do not convert
do not convert
do not
prohibit
any size
-
-
-
0007-5659
0007-5660
0007-5661